Application of some semi-active control algorithms to a smart base-isolated building employing MR dampers
Authors:
- Hyung-Jo JungHJHyung-Jo Jung
- Billie F. SpencerBSBillie F. Spencer
- 7 November 2005
- journal article
- research article
- Published by Hindawi Limited in Structural Control and Health Monitoring
- Vol. 13 (2-3) , 693-704
Abstract
This paper investigates the effectiveness of the MR damper-based control systems for seismic protection of base-isolated building structures employing some semi-active control algorithms, such as the modified clipped-optimal control, the maximum energy dissipation, the modulated homogeneous friction, and fuzzy logic-based control algorithms, by examining the Phase I smart base-isolated benchmark building problem. The results of the numerical simulations showed that most of the control systems considered herein could be beneficial in reducing seismic responses, especially the base displacement or the isolator deformation, of the base-isolated building. If the base displacement is to be primarily reduced without regard to variation of the floor acceleration, the original clipped-optimal control algorithm could be recommended. On the other hand, if it may be required to reduce the base displacement without increasing the floor acceleration, the modified clipped-optimal control algorithm proposed in this study could be considered as one promising candidate for the linear benchmark base-isolated system. Copyright © 2005 John Wiley & Sons, Ltd.Keywords
This publication has 9 references indexed in Scilit:
- Seismic Control of a Nonlinear Benchmark Building Using Smart DampersJournal of Engineering Mechanics, 2004
- Semi‐active fuzzy control for seismic response reduction using magnetorheological dampersEarthquake Engineering & Structural Dynamics, 2004
- “Smart” Base Isolation SystemsJournal of Engineering Mechanics, 2002
- Semiactive Control Strategies for MR Dampers: Comparative StudyJournal of Engineering Mechanics, 2000
- Fuzzy control of structural vibration. An active mass system driven by a fuzzy controllerEarthquake Engineering & Structural Dynamics, 1998
- MODULATED HOMOGENEOUS FRICTION: A SEMI-ACTIVE DAMPING STRATEGYEarthquake Engineering & Structural Dynamics, 1997
- Modeling and control of magnetorheological dampers for seismic response reductionSmart Materials and Structures, 1996
- Control of Sliding-Isolated Buildings Using Sliding-Mode ControlJournal of Structural Engineering, 1996
- Passive and Active Structural Vibration Control in Civil Engineering1994