A comparison of DXA and CT based methods for estimating the strength of the femoral neck in post-menopausal women
- 19 July 2012
- journal article
- research article
- Published by Springer Nature in Osteoporosis International
- Vol. 24 (4) , 1379-1388
Abstract
Summary The study goal was to compare simple two-dimensional (2D) analyses of bone strength using dual energy x-ray absorptiometry (DXA) data to more sophisticated three-dimensional (3D) finite element analyses using quantitative computed tomography (QCT) data. DXA- and QCT-derived femoral neck geometry, simple strength indices, and strength estimates were well correlated. Introduction Simple 2D analyses of bone strength can be done with DXA data and applied to large data sets. We compared 2D analyses to 3D finite element analyses (FEA) based on QCT data. Methods Two hundred thirteen women participating in the Study of Women's Health Across the Nation (SWAN) received hip DXA and QCT scans. DXA BMD and femoral neck diameter and axis length were used to estimate geometry for composite bending (BSI) and compressive strength (CSI) indices. These and comparable indices computed by Hip Structure Analysis (HSA) on the same DXA data were compared to indices using QCT geometry. Simple 2D engineering simulations of a fall impacting on the greater trochanter were generated using HSA and QCT femoral neck geometry; these estimates were benchmarked to a 3D FEA of fall impact. Results DXA-derived CSI and BSI computed from BMD and by HSA correlated well with each other (R = 0.92 and 0.70) and with QCT-derived indices (R = 0.83–0.85 and 0.65–0.72). The 2D strength estimate using HSA geometry correlated well with that from QCT (R = 0.76) and with the 3D FEA estimate (R = 0.56). Conclusions Femoral neck geometry computed by HSA from DXA data corresponds well enough to that from QCT for an analysis of load stress in the larger SWAN data set. Geometry derived from BMD data performed nearly as well. Proximal femur breaking strength estimated from 2D DXA data is not as well correlated with that derived by a 3D FEA using QCT data.Keywords
This publication has 28 references indexed in Scilit:
- An in vivo comparison of hip structure analysis (HSA) with measurements obtained by QCTOsteoporosis International, 2011
- High resolution cortical bone thickness measurement from clinical CT dataMedical Image Analysis, 2010
- Age-dependence of femoral strength in white women and menJournal of Bone and Mineral Research, 2010
- During sideways falls proximal femur fractures initiate in the superolateral cortex: Evidence from high-speed video of simulated fracturesJournal of Biomechanics, 2009
- Assessing the Susceptibility to Local Buckling at the Femoral Neck Cortex to Age-Related Bone LossAnnals of Biomedical Engineering, 2009
- Finite Element Analysis of the Proximal Femur and Hip Fracture Risk in Older MenJournal of Bone and Mineral Research, 2009
- Femoral Bone Strength and Its Relation to Cortical and Trabecular Changes After Treatment With PTH, Alendronate, and Their Combination as Assessed by Finite Element Analysis of Quantitative CT ScansJournal of Bone and Mineral Research, 2008
- Incidence and Economic Burden of Osteoporosis-Related Fractures in the United States, 2005–2025Journal of Bone and Mineral Research, 2007
- Trabecular bone modulus–density relationships depend on anatomic siteJournal of Biomechanics, 2003
- Non-invasive measurement of long bone cross-sectional moment of inertia by photon absorptiometryJournal of Biomechanics, 1984