Investigation of Steady-State Heat Extraction Rates for Different Borehole Heat Exchanger Configurations from the Aspect of Implementation of New TurboCollector™ Pipe System Design
Open Access
Abstract
When considering implementation of shallow geothermal energy as a renewable source for heating and cooling of buildings, special care should be taken in the hydraulic design of the borehole heat exchanger system. Laminar flow can occur in pipes due to the usage of glycol mixtures at low temperature or inadequate flow rates. This can lead to lower heat extraction and rejection rates of the exchanger because of higher thermal resistance. Furthermore, by increasing the flow rate to achieve turbulent flow and satisfactory heat transfer rate can lead to an increase in the pressure drop of the system and oversizing of the circulation pump which leads to impairment of the seasonal coefficient of performance at the heat pump. The most frequently used borehole heat exchanger system in Europe is a double-loop pipe system with a smooth inner wall. Lately, development is focused on the implementation of a different configuration as well as with ribbed inner walls which ensures turbulent flow in the system, even at lower flow rates. At a location in Zagreb, standard and extended thermal response tests were conducted on three different heat exchanger configurations in the same geological environment. With a standard TRT test, thermogeological properties of the ground and thermal resistance of the borehole were determined for each smooth or turbulator pipe configuration. On the other hand, extended Steady-State Thermal Response Step Test (TRST) incorporates a series of power steps to determine borehole extraction rates at the defined steady-state heat transfer conditions of 0/−3 °C. When comparing most common exchanger, 2U-loop D32 smooth pipe, with novel 1U-loop D45 ribbed pipe, an increase in heat extraction of 6.5% can be observed. Also, when the same comparison is made with novel 2U-loop D32 ribbed pipe, an increase of 18.7% is achieved. Overall results show that heat exchangers with ribbed inner pipe wall have advantages over classic double-loop smooth pipe designs, in terms of greater steady-state heat extraction rate and more favorable hydraulic conditions.Keywords
All Related Versions
This publication has 24 references indexed in Scilit:
- How Reliable Are Standard Thermal Response Tests? An Assessment Based on Long-Term Thermal Response Tests Under Different Operational ConditionsEnergies, 2018
- Ground Thermal Response and Recovery after Heat Injection: Experimental InvestigationTransactions of FAMENA, 2018
- Use of temperature derivative to analyze thermal response tests on borehole heat exchangersApplied Thermal Engineering, 2018
- Interpretation of the first hours of a thermal response test using the time derivative of the temperatureApplied Energy, 2018
- STEADY-STATE HEAT REJECTION RATES FOR A COAXIAL BOREHOLE HEAT EXCHANGER DURING PASSIVE AND ACTIVE COOLING DETERMINED WITH THE NOVEL STEP THERMAL RESPONSE TEST METHODRudarsko-geološko-naftni zbornik, 2018
- Applying Petroleum the Pressure Buildup Well Test Procedure on Thermal Response Test—A Novel Method for Analyzing Temperature Recovery PeriodEnergies, 2018
- Validation of borehole heat exchanger models against multi-flow rate thermal response testsGeothermics, 2018
- Evaluation of the Internal and Borehole Resistances during Thermal Response Tests and Impact on Ground Heat Exchanger DesignEnergies, 2017
- On the Influence of Operational and Control Parameters in Thermal Response Testing of Borehole Heat ExchangersEnergies, 2017
- Thermal Response Testing Results of Different Types of Borehole Heat Exchangers: An Analysis and Comparison of Interpretation MethodsEnergies, 2017