Surface profiling of an aspherical liquid lens with a varied thickness membrane
Authors:
Open Access
- 6 February 2017
- journal article
- research article
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (4) , 3122-3132
Abstract
Inspired by crystalline lenses in human eyes, liquid lenses have a simple yet elegant working principle, and result in compact optical systems. Recent numerical studies showed that membranes with variable thicknesses could affect the lens profile. However, fabrication and assembly of a liquid lens with an inhomogeneous membrane is difficult. There is also a lack of experimental studies about the changes of a lens profile during deformation. In this paper, we provided a new experimental approach for characterizing the performance of a liquid lens with an inhomogeneous membrane. A 2D axisymmetric lens model was built in finite element analysis software to theoretically study the non-linear deformation behavior of the inhomogeneous membrane. Then we provided a new approach to fabricate inhomogeneous membranes using a pre-machined aluminum mold. An optical coherence tomography (OCT) system was used to dynamically measure the changes of a lens profile without contact. Both simulation and the experiments indicated that the variation of the thickness of the membrane could affect the lens profile in a predictable manner. A negative conic constant was achieved when a plano-concave membrane was adopted in a liquid lens. Larger increments of the thickness of the membrane in the radial direction resulted in a larger contribution of a conic constant to the lens profile. The presented study offers guidance for image-quality analysis and optimization of a liquid-lens-based optical system.Keywords
Funding Information
- Jiangsu Provincial Department of Education (16KJA510002)
- National Key Research and Development Program of China (2016YFF0201005)
- National Natural Science Foundation of China (NSFC) (61401292)
- Natural Science Foundation of Jiangsu Province (BK20140350)
- Priority Academic Program Development of Jiangsu Higher Education Institutions
This publication has 26 references indexed in Scilit:
- Optical axial scanning in confocal microscopy using an electrically tunable lensBiomedical Optics Express, 2014
- Nonmechanical zoom system through pressure-controlled tunable fluidic lensesApplied Optics, 2013
- Analysis of two-element zoom systems based on variable power lensesOptics Express, 2010
- Fluidic lens laparoscopic zoom camera for minimally invasive surgeryJournal of Biomedical Optics, 2010
- Bio-inspired accommodating fluidic intraocular lensOptics Letters, 2009
- Fabrication of a fluidic membrane lens systemJournal of Micromechanics and Microengineering, 2009
- Optical characterization of adaptive fluidic silicone-membrane lensesOptics Express, 2009
- Fluidic Intraocular Lens With a Large Accommodation RangeIEEE Photonics Technology Letters, 2009
- Three-dimensional adaptive microscopy using embedded liquid lensOptics Letters, 2009
- Tunable liquid-filled microlens array integrated with microfluidic networkOptics Express, 2003