Harmonic Interaction Influence Due to Current Source Shunt Filters in Networks Supplying Nonlinear Loads
Authors:
- 20 March 2012
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 27 (3) , 1385-1393
Abstract
The increase of nonlinear loads (NLLs) in supply networks has led to an increase of harmonic content in supply currents. To keep current distortion within the limits fixed by international standards, several filtering solutions have been proposed, the most advanced consisting of active power-line conditioners (APLCs) which cancel the reactive components and harmonic currents. The control and sizing of APLC equipment are based on the hypothesis that NLLs behave as “current sources” whose ripple may be canceled by injecting a counter-phase set of harmonic currents. Nevertheless, the internal impedance of the distribution network influences the real behavior of NLLs, so that when the APLC controller tries to cancel harmonic currents at a global level, harmonics generated by the NLLs increase. This paper is devoted to the analysis and quantification of this phenomenon related to the attenuation phenomenon and the attenuation factor.Keywords
This publication has 30 references indexed in Scilit:
- Optimal multiobjective planning of large-scale passive harmonic filters using hybrid differential evolution method considering parameter and loading uncertaintyIEEE Transactions on Power Delivery, 2005
- Harmonic Interaction Between a Large Number of Distributed Power Inverters and the Distribution NetworkIEEE Transactions on Power Electronics, 2004
- Selective Active Filter With Optimum Remote Harmonic Distortion ControlIEEE Transactions on Power Delivery, 2004
- Implementation and performance of cooperative control of shunt active filters for harmonic damping throughout a power distribution systemIEEE Transactions on Industry Applications, 2003
- Harmonic SourcesIEEE Industry Applications Magazine, 2001
- Passive filter design for harmonic reactive power compensation in single-phase circuits supplying nonlinear loadsIEE Proceedings - Generation, Transmission and Distribution, 2000
- Passive shunt harmonic filters for low and medium voltage: a cost comparison studyIEEE Transactions on Power Systems, 1996
- Effect of supply voltage harmonics on the input current of single-phase diode bridge rectifier loadsIEEE Transactions on Power Delivery, 1995
- An investigation of harmonics attenuation and diversity among distributed single-phase power electronic loadsIEEE Transactions on Power Delivery, 1995
- Harmonic interaction between generation and transmission systemsIEEE Transactions on Power Delivery, 1993