Electrochemical Sensor for Selective Detection of Meldonium in Urine by Voltammetry
- 11 October 2022
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 35 (4)
Abstract
A highly sensitive electrochemical sensor based on arenediazonium tosylates was designed to detect meldonium in urine. The effect of the concentration of ArN2+OTs− arenediazonium tosylate modifier and various substituents was studied. Basic operating parameters for voltammetric meldonium detection were established and the procedure for urine sample preparation was developed. The following values were obtained: limit of detection (LOD) 0.005 mg ⋅ L−1 (P=0.95) and limit of quantification (LOQ) 0.01 mg ⋅ L−1. The relationship between the analytical signal and meldonium concentration in the solution ranging from 0.01 to 400 mg ⋅ L−1 was described by a linear function. The meldonium concentration error did not exceed 18 %. The analysis time for a single urine sample was reduced to 15 minutes.Keywords
Funding Information
- Tomsk Polytechnic University (20.0025.GZB.2020)
This publication has 16 references indexed in Scilit:
- Urinary excretion studies of meldonium after multidose parenteral applicationJournal of Pharmaceutical and Biomedical Analysis, 2018
- Pharmacological effects of meldonium: Biochemical mechanisms and biomarkers of cardiometabolic activityPharmacological Research, 2016
- Rapid determination of meldonium in urine samples by capillary electrophoresis with capacitively coupled contactless conductivity detectionJournal of Chromatography A, 2016
- Mildronate (Meldonium) in professional sports – monitoring doping control urine samples using hydrophilic interaction liquid chromatography – high resolution/high accuracy mass spectrometryDrug Testing and Analysis, 2015
- First examples of arenediazonium 4-dodecylbenzenesulfonates: synthesis and characterizationRussian Chemical Bulletin, 2014
- UPLC‐MS/MS method for bioequivalence study of oral drugs of meldoniumBiomedical Chromatography, 2011
- Determination of mildronate by LC–MS/MS and its application to a pharmacokinetic study in healthy Chinese volunteersJournal of Chromatography B, 2010
- Determination of mildronate in human plasma and urine by liquid chromatography–tandem mass spectrometryJournal of Chromatography B, 2007
- Electrochemical Modification of Glassy Carbon Electrode Using Aromatic Diazonium Salts. 1. Blocking Effect of 4-Nitrophenyl and 4-Carboxyphenyl GroupsLangmuir, 1997
- HPLC analysis of mildronate and its analogues in plasmaJournal of Pharmaceutical and Biomedical Analysis, 1993