Abstract
(1) Background: Limited data exist on the safety and efficacy of epicardial left ventricular (LV) lead placement using video-assisted thoracoscopic surgery (VATS) for cardiac resynchronization therapy (CRT). (2) Methods: Acute and post-discharge outcomes of CRT were compared between patients with epicardial LV leads (Epicardial-LV group, n = 13) and those with endocardial LV leads (Endocardial-LV group, n = 243). (3) Results: Epicardial LV leads were implanted via VATS alone (n = 8) or along with mini-thoracotomy (n = 5), for failed endocardial implantation (n = 11) or recurrent lead dislodgement (n = 2). All epicardial procedures under general anesthesia with one-lung ventilation were successfully completed in 1.0 ± 0.4 h without phrenic nerve stimulation. LV pacing thresholds in the epicardial-LV (1.5 ± 1.0 V) and endocardial-LV (1.3 ± 0.8 V) were comparable (p = 0.651). All patients were discharged alive post-VATS 8.8 ± 3.9 days. During the follow-up (34.3 ± 28.6 months), all patients with epicardial LV leads stayed alive except for one cardiac death post-CRT 14 months and one heart transplantation post-CRT 30 months. All epicardial LV leads maintained stable performance without dislodgement/significant changes in pacing threshold/impedance. LV lead dislodgement occurred only in endocardial-LV (7/243, 2.9%). Efficacy in both groups was comparable in terms of QRS narrowing, increase in LV ejection fraction, and survival free of cardiac death, or heart-failure-related hospitalization. (4) Conclusions: Epicardial LV lead placement using VATS can be a safe and effective alternative to endocardial implantation, with comparable acute and post-discharge outcomes achieved by both approaches.Keywords
All Related Versions
This publication has 25 references indexed in Scilit:
- Minimally Invasive Implantation of the Myopore Sutureless Myocardial Pacing LeadInnovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2012
- Thoracoscopic Left Ventricular Lead Implantation in Cardiac Resynchronization TherapyJournal of Korean Medical Science, 2012
- Long-Term Effectiveness of Cardiac Resynchronization Therapy in Heart Failure Patients With Unfavorable Cardiac Veins AnatomyJACC, 2011
- Left Ventricular Lead Position and Clinical Outcome in the Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy (MADIT-CRT) TrialCirculation, 2011
- Cardiac-Resynchronization Therapy for Mild-to-Moderate Heart FailureNew England Journal of Medicine, 2010
- Video‐Assisted Thoracoscopic Implantation of the Left Ventricular Pacing Lead for Cardiac Resynchronization TherapyPacing and Clinical Electrophysiology, 2008
- Minimally Invasive Left Ventricular Epicardial Lead Placement: Surgical Techniques for Heart Failure Resynchronization TherapyThe Annals of Thoracic Surgery, 2005
- The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart FailureNew England Journal of Medicine, 2005
- Epicardial left ventricular lead placement for cardiac resynchronization therapy: optimal pace site selection with pressure-volume loopsThe Journal of Thoracic and Cardiovascular Surgery, 2004
- Cardiac-Resynchronization Therapy with or without an Implantable Defibrillator in Advanced Chronic Heart FailureNew England Journal of Medicine, 2004