Perforation risk and intra-uterine devices: results of the EURAS-IUD 5-year extension study
Authors:
- 2 November 2017
- journal article
- research article
- Published by Taylor & Francis in The European Journal of Contraception & Reproductive Health Care
- Vol. 22 (6) , 424-428
Abstract
Objectives: The objective of this analysis was to identify intra-uterine devices (IUD) perforations detected from 12 to 60 months following IUD insertion, and to combine this information with (our previously published) data about perforations detected in the first 12 months to calculate cumulative perforation rates. Methods and materials: Prospective, non-interventional cohort study with new users of levonorgestrel-releasing intra-uterine systems (LNG-IUS) and copper-IUD. The original cohort included 61,448 women followed for 12 months. Of these, we had sufficient resources to perform an additional follow-up and analysis at 60 months in 39,009 women. Inclusion criteria for this analysis was insertion prior to 31 July 2010. All potential cases were validated via the health care professional or medical records. Crude and adjusted relative risks were calculated using a logistic regression model. Results: We identified 23 additional perforations (19 LNG-IUS and 4 copper-IUD) more than 12 months after insertion. Added to perforations detected at 12 months, the overall perforation rate was 2.1 per 1000 insertions (95% CI: 1.6–2.8) for LNG-IUS users (40 + 19 perforations/27,630 insertions) and 1.6 per 1000 insertions (95% CI: 0.9–2.5) for copper-IUD users (14 + 4 perforations/11,379 insertions). LNG-IUS users had a borderline higher risk of perforation compared with copper-IUD users (ORadj 1.7; 95% CI: 1.0–2.8). Forty-five (58%) of the 77 perforations were associated with suspected risk factors. Breastfeeding (RR 4.9, 95% CI: 3.0–7.8) and time since delivery (RR 3.0, CI: 1.5–5.4) remained significant risk factors in perforations detected after 12 months. No perforations resulted in serious injury to intra-abdominal or pelvic structures. Conclusions: The incidence of uterine perforations in this study was low, although higher than the commonly reported rate. Approximately one third of perforations are detected 12 months after insertion. Clinical sequalae of perforations are generally mild and associated with a very low risk of injury to intra-abdominal and pelvic structures.Keywords
Funding Information
- Bayer
This publication has 11 references indexed in Scilit:
- IUD use among parous women and risk of uterine perforation: a secondary analysisContraception, 2017
- Comparative contraceptive effectiveness of levonorgestrel-releasing and copper intrauterine devices: the European Active Surveillance Study for Intrauterine DevicesContraception, 2015
- Risk of uterine perforation with levonorgestrel-releasing and copper intrauterine devices in the European Active Surveillance Study on Intrauterine DevicesContraception, 2015
- False Alarms and Pseudo-EpidemicsObstetrics & Gynecology, 2012
- Healthy User and Related Biases in Observational Studies of Preventive Interventions: A Primer for PhysiciansJournal of General Internal Medicine, 2011
- Uterine Perforation with the Levonorgestrel-Releasing Intrauterine DeviceDrug Safety, 2011
- Causation, bias and confounding: a hitchhiker's guide to the epidemiological galaxy.BMJ Sexual & Reproductive Health, 2008
- Causation, bias and confounding: a hitchhiker's guide to the epidemiological galaxy Part 2. Principles of causality in epidemiological research: confounding, effect modification and strength of associationBMJ Sexual & Reproductive Health, 2008
- Strengthening the reporting of observational studies in epidemiology (STROBE) statement: guidelines for reporting observational studiesBMJ, 2007
- Interpretation of recurring weak associations obtained from epidemiologic studies of suspected human teratogensTeratology, 1992