Hemodynamic Effects of Left Atrial or Left Ventricular Cannulation for Acute Circulatory Support in a Bovine Model of Left Heart Injury
Authors:
- 1 May 2015
- journal article
- adult circulatory-support
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 61 (3) , 301-306
Abstract
Our objective was to examine the hemodynamic effects of a trans-aortic axial flow catheter (Impella CP) in the left ventricle (LV) versus left atrial (LA) to femoral artery bypass using a centrifugal pump (TandemHeart: TH) in a bovine model of acute LV injury. In three male calves, we performed sequential activation of a CP then TH device in each animal. After 60 minutes of left anterior descending artery ligation, a CP was activated at maximal power. The CP was then removed and the TH activated at 5,500 then a maximum of 7,500 rotations per minute (RPM). The CP generated a maximum 3.1 ± 0.2 L/minute (LPM) of flow, whereas the TH at 5,500 and 7,500 RPM generated 3.1 ± 0.4 and 4.4 ± 0.3 LPM. At 3.1 LPM, the CP and TH reduced LV stroke work (LVSW) similarly. The TH reduced stroke volume, whereas the CP did not. The CP reduced end-systolic pressure, whereas the TH did not. At a maximum flow of 4.4 LPM, the TH provided a greater reduction in LVSW than maximal CP activation. This is the first report to compare the hemodynamic effects of trans-aortic LV unloading versus LA-to-femoral artery (FA) bypass.Keywords
This publication has 15 references indexed in Scilit:
- Sixth INTERMACS annual report: A 10,000-patient databaseThe Journal of Heart and Lung Transplantation, 2014
- Mechanical circulatory support in cardiogenic shockEuropean Heart Journal, 2013
- The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: Executive summaryThe Journal of Heart and Lung Transplantation, 2013
- Heart rescueCurrent Opinion in Critical Care, 2012
- The science behind percutaneous hemodynamic support: A review and comparison of support strategiesCatheterization and Cardiovascular Interventions, 2012
- The Percutaneous Ventricular Assist Device in Severe Refractory Cardiogenic ShockJACC, 2011
- Implantation of an Elastic Ring at Equator of the Left Ventricle Influences Cardiac Mechanics in Experimental Acute Ventricular DysfunctionJACC, 2007
- Left Ventricular Pressure-Volume Relationships Before and After Cardiomyoplasty in Patients With Heart FailureCirculation, 1997
- Determination of left ventricular end-systolic pressure-volume relationships by the conductance (volume) catheter technique.Circulation, 1986
- Continuous measurement of left ventricular volume in animals and humans by conductance catheter.Circulation, 1984