Predictors of Restenosis After Implantation of 2.5 mm Stents in Small Coronary Arteries
Authors:
Open Access
- 1 January 2004
- journal article
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 68 (3) , 236-240
Abstract
Background The results of stent implantation for small coronary disease have been inconclusive. The purpose of the present study was to evaluate the factors in predicting the risk of angiographic restenosis after 2.5-mm stent implantation for small coronary arteries. Methods and Results The study group comprised 134 consecutive patients who had a reference small coronary artery with diameter from 1.8 mm to 2.5 mm on quantitative coronary angiography and who had been successfully treated by stent implantation with a 2.5-mm stent. Of the 134 patients, 55 had angiographic restenosis (41%). The rate of target lesion revascularization was 32%. Diabetes mellitus, acute coronary syndrome, lesion length, bifurcation lesion, lower left ventricular ejection fraction (LVEF), stent strut, stent/artery ratio, and stent length were identified as predictors of restenosis by univariate analysis. Subsequent multivariate analysis revealed that lower LVEF (odds ratio (OR) 3.37, p=0.01), bifurcation lesion (OR 2.47, p=0.04), thicker stent strut (OR 2.30, p=0.04), and longer stent length (OR 1.05, p=0.02) were significant predictors of restenosis. Conclusions Two pre-interventional factors (reduced left ventricular function and bifurcated lesion) and 2 procedure-related factors (thickness of stent strut and total stent length) were identified as predictors of restenosis. These factors should be taken into account when deciding on the percutaneous coronary intervention strategy for small coronary artery disease. (Circ J 2004; 68: 236 - 240)Keywords
This publication has 24 references indexed in Scilit:
- Angiographic Findings of the Multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL)Circulation, 2002
- Intravascular Ultrasound Findings in the Multicenter, Randomized, Double-Blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) TrialCirculation, 2002
- A Randomized Comparison of a Sirolimus-Eluting Stent with a Standard Stent for Coronary RevascularizationNew England Journal of Medicine, 2002
- Stent Placement Compared With Balloon Angioplasty for Small Coronary ArteriesCirculation, 2001
- A Randomized Trial Comparing Stenting With Balloon Angioplasty in Small Vessels in Patients With Symptomatic Coronary Artery DiseaseCirculation, 2000
- Vessel Size and Long-Term Outcome After Coronary Stent PlacementCirculation, 1998
- Angiographic and clinical outcome following coronary stenting of small vesselsJACC, 1998
- Efficacy of Coronary Stenting Versus Balloon Angioplasty in Small Coronary ArteriesJACC, 1998
- Endogenous Cell SeedingCirculation, 1996
- Restenosis and the proportional neointimal response to coronary artery injury: Results in a porcine modelJACC, 1992