Quantitative measurement of cerebral blood volume using velocity‐selective pulse trains
Authors:
- 31 October 2016
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (1) , 92-101
Abstract
Purpose: To develop a non–contrast‐enhanced MRI method for cerebral blood volume (CBV) mapping using velocity‐selective (VS) pulse trains.Methods: The new pulse sequence applied velocity‐sensitive gradient waveforms in the VS label modules and velocity‐compensated ones in the control scans. Sensitivities to the gradient imperfections (e.g., eddy currents) were evaluated through phantom studies. CBV quantification procedures based on simulated labeling efficiencies for arteriolar, capillary, and venular blood as a function of cutoff velocity (Vc) are presented. Experiments were conducted on healthy volunteers at 3T to examine the effects of unbalanced diffusion weighting, cerebrospinal (CSF) contamination and variation of Vc.Results: Phantom results of the used VS pulse trains demonstrated robustness to eddy currents. The mean CBV values of gray matter and white matter for the experiments using Vc = 3.5 mm/s and velocity‐compensated control with CSF‐nulling were 5.1 ± 0.6 mL/100 g and 2.4 ± 0.2 mL/100 g, respectively, which were 23% and 32% lower than results from the experiment with velocity‐insensitive control, corresponding to 29% and 25% lower in averaged temporal signal‐to‐noise ratio values.Conclusion: A novel technique using VS pulse trains was demonstrated for CBV mapping. The results were both qualitatively and quantitatively close to those from existing methods. Magn Reson Med 77:92–101, 2017. © 2016 International Society for Magnetic Resonance in MedicineKeywords
Funding Information
- National Heart, Lung, and Blood Institute (K25 HL121192)
- National Institutes of Health (P41 EB015909)
- American Society of Hematology (Scholar Award)
This publication has 76 references indexed in Scilit:
- QUantitative Imaging of eXtraction of oxygen and TIssue consumption (QUIXOTIC) using venular‐targeted velocity‐selective spin labelingMagnetic Resonance in Medicine, 2011
- Measurement of absolute arterial cerebral blood volume in human brain without using a contrast agentNMR in Biomedicine, 2011
- Calibration and validation of TRUST MRI for the estimation of cerebral blood oxygenationMagnetic Resonance in Medicine, 2011
- Inflow‐based vascular‐space‐occupancy (iVASO) MRIMagnetic Resonance in Medicine, 2011
- Fast measurement of bloodT1in the human jugular vein at 3 TeslaMagnetic Resonance in Medicine, 2010
- Determination of whole‐brain oxygen extraction fractions by fast measurement of blood T2 in the jugular veinMagnetic Resonance in Medicine, 2010
- 3D noncontrast MR angiography of the distal lower extremities using flow‐sensitive dephasing (FSD)‐prepared balanced SSFPMagnetic Resonance in Medicine, 2009
- On the measurement of absolute cerebral blood volume (CBV) using vascular‐space‐occupancy (VASO) MRIMagnetic Resonance in Medicine, 2008
- Continuous flow‐driven inversion for arterial spin labeling using pulsed radio frequency and gradient fieldsMagnetic Resonance in Medicine, 2008
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996