Optimal weak measurement scheme for chiral molecular detection based on photonic spin Hall effect
- 14 November 2023
- journal article
- research article
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (24) , 40308-40316
Abstract
In this paper, we propose a precision method to measure the chiroptical signal of Artemisinin solutions using the photonic spin Hall effect (PSHE) on the Ce:YIG-YIG-SiO2 structure as a probe. The effects of transmission distance, incident angles, applied magnetic fields of different directions, and beam waist of light on the weak measurement system are analytically investigated through simulations. It is found that decreasing the beam waist of the incident spot, increasing the incident angle, increasing the transmission distance, and adding a longitudinal magnetic field is conducive to enhancing the amplification transverse shift of PSHE, thus the measurement sensitivity is greatly improved. Based on the optimal weak measurement scheme, the detection limit for concentration measurement of artemisinin based on optical rotatory (OR) was reduced to 0.05 mg/ml. The measurement precision of the OR angle has been improved to 10−7 rad.Keywords
Funding Information
- National Natural Science Foundation of China (62175021)
- Chengdu Technology Innovation and Research and Development Project (2021-YF05-02420-GX, 2021-YF05-02422-GX, 2021-YF08-00159-GX)
- Scientific Research Foundation of Chengdu University of Information Technology (KYTZ202244)
This publication has 30 references indexed in Scilit:
- Neuropharmacological Screening of Chiral and Non-chiral Phthalimide- Containing Compounds in Mice: in vivo and in silico ExperimentsMedicinal Chemistry, 2019
- Last ten years (2008–2018) of chiral ligand‐exchange chromatography in HPLC: An updated reviewJournal of Separation Science, 2018
- Optical rotation based chirality detection of enantiomers via weak measurement in frequency domainApplied Physics Letters, 2018
- Quantitative detection of the respective concentrations of chiral compounds with weak measurementsApplied Physics Letters, 2017
- Estimation of optical rotation of chiral molecules with weak measurementsOptics Letters, 2016
- Determination of the focused beam waist of lasers with weak measurementsChinese Optics Letters, 2015
- Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value AmplificationPhysical Review Letters, 2009
- Observation of the Spin Hall Effect of Light via Weak MeasurementsScience, 2008
- Chiral Molecules Split Light: Reflection and Refraction in a Chiral LiquidPhysical Review Letters, 2006
- Determination of absolute configuration using ab initio calculation of optical rotationChirality, 2003