Dynamic autofocus for continuous-scanning time-delay-and-integration image acquisition in automated microscopy
Authors:
- 1 January 2007
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 12 (3) , 034011-034011-16
Abstract
Efficient image cytometry of a conventional microscope slide means rapid acquisition and analysis of 20 gigapixels of image data (at sampling). The voluminous data motivate increased acquisition speed to enable many biomedical applications. Continuous-motion time-delay-and-integrate (TDI) scanning has the potential to speed image acquisition while retaining sensitivity, but the challenge of implementing high-resolution autofocus operating simultaneously with acquisition has limited its adoption. We develop a dynamic autofocus system for this need using: 1. a “volume camera,” consisting of nine fiber optic imaging conduits to charge-coupled device (CCD) sensors, that acquires images in parallel from different focal planes, 2. an array of mixed analog-digital processing circuits that measure the high spatial frequencies of the multiple image streams to create focus indices, and 3. a software system that reads and analyzes the focus data streams and calculates best focus for closed feedback loop control. Our system updates autofocus at (or once every of stage travel) to collect sharply focused images sampled at /pixel at a stage speed of . The system, tested by focusing in phase contrast and imaging long fluorescence strips, achieves high-performance closed-loop image-content-based autofocus in continuous scanning for the first time.
Keywords
This publication has 22 references indexed in Scilit:
- Plasma Membrane Assays And Three-Compartment Image Cytometry for High Content ScreeningASSAY and Drug Development Technologies, 2007
- Laser autofocusing system for high‐resolution cell biological imagingJournal of Microscopy, 2006
- High‐throughput laser‐mediated in situ cell purification with high purity and yieldCytometry Part A, 2004
- Distinguishing modes of cell death using the ImageStream® multispectral imaging flow cytometerCytometry Part A, 2004
- Method for evaluation of imaging in automated visual web inspectionOptical Engineering, 1997
- Analysis of MTF degradation in the imaging of cells in a flow systemInternational Journal of Imaging Systems and Technology, 1994
- Comparison of phase‐contrast and fluorescence digital autofocus for scanning microscopyCytometry, 1994
- The PSI Automatic Metaphase FinderJournal of Radiation Research, 1992
- Comparison of autofocus methods for automated microscopyCytometry, 1991
- A comparison of different focus functions for use in autofocus algorithmsCytometry, 1985