Shortening of freezing cycles provides equal outcome to standard ablation procedure using second-generation 28 mm cryoballoon after 15-month follow-up
- 11 June 2015
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (2) , 206-210
Abstract
Aims Complications such as thermal oesophageal lesions, phrenic nerve injury, and pulmonary haemorrhage were found in cryoballoon (CB) ablation. Whether shortening of freezing times translates into equal efficacy rate and outcome is unknown. The aim of this study was to test the hypothesis that a single freeze cycle per pulmonary vein (PV) without dormant conduction during adenosine infusion is equally effective to standard CB procedure with a bonus freeze after documented PV isolation (PVI). Methods and results In 53 patients with drug-refractory atrial fibrillation (AF) demonstrating PVI after a single 240 s freeze cycle without PV activity during adenosine no additional bonus freeze was applied (study group). In 139 patients, PVI was performed using a bonus freeze (240 s) after documented PVI (control group). Primary endpoint was recurrence of AF. Secondary endpoint was the assessment of quality of life (QoL-score from 1 to 6, being 1 the best and 6 the worst). Follow-up (FU) was performed at 3, 6, and 12 months. Freedom from symptomatic AF during a mean FU of 458 ± 107 days was achieved in 43 (81%) patients in the study group and in 110 (79%) control patients ( P = ns). The QoL-score improved equally in both groups (4.8 ± 0.9 to 2.1 ± 0.7, P < 0.05 and 4.7 ± 0.6 to 2.2 ± 0.6, P < 0.05). Procedure duration (79 ± 14 vs. 98 ± 16 min, P < 0.01) was shorter in the study group. Complication rate was similar in both groups. Conclusion Shortening of freezing times to 4 min per PV without residual dormant PV conduction after adenosine provocation is equally effective to the standard CB ablation protocol using a bonus freeze.Keywords
This publication has 25 references indexed in Scilit:
- The Incidence of Phrenic Nerve Injury During Pulmonary Vein Isolation Using the Second‐Generation 28 mm CryoballoonJournal of Cardiovascular Electrophysiology, 2014
- Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-upEP Europace, 2014
- Atrioesophageal Fistula During Cryoballoon Ablation for Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2014
- Pulmonary Hemorrhage After Cryoballoon Ablation for Pulmonary Vein Isolation in the Treatment of Atrial FibrillationChest, 2014
- Phrenic nerve paralysis during cryoballoon ablation for atrial fibrillation: A comparison between the first- and second-generation balloonHeart Rhythm, 2013
- Increased Incidence of Esophageal Thermal Lesions Using the Second-Generation 28-mm CryoballoonCirculation: Arrhythmia and Electrophysiology, 2013
- Luminal esophageal temperature predicts esophageal lesions after second-generation cryoballoon pulmonary vein isolationHeart Rhythm, 2013
- Pulmonary Vein Isolation Using a Second‐Generation Cryoballoon Catheter: A Randomized Comparison of Ablation Duration and Method of DeflationJournal of Cardiovascular Electrophysiology, 2013
- Improved Procedural Efficacy of Pulmonary Vein Isolation Using the Novel Second‐Generation CryoballoonJournal of Cardiovascular Electrophysiology, 2012
- Adenosine testing after cryoballoon pulmonary vein isolation improves long-term clinical outcomeNetherlands Heart Journal, 2012