Introduce a rotational robust optimization framework for spot-scanning proton arc (SPArc) therapy
- 22 December 2022
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (1) , 01NT02
Abstract
Objective. Proton dosimetric uncertainties resulting from the patient’s daily setup errors in rotational directions exist even with advanced image-guided radiotherapy techniques. Thus, we developed a new rotational robust optimization SPArc algorithm (SPArcrot) to mitigate the dosimetric impact of the rotational setup error in Raystation ver. 6.02 (RaySearch Laboratory AB, Stockholm, Sweden). Approach. The initial planning CT was rotated ±5° simulating the worst-case setup error in the roll direction. The SPArcrot uses a multi-CT robust optimization framework by taking into account of such rotational setup errors. Five cases representing different disease sites were evaluated. Both SPArcoriginal and SPArcrot plans were generated using the same translational robust optimized parameters. To quantitatively investigate the mitigation effect from the rotational setup errors, all plans were recalculated using a series of pseudo-CT with rotational setup error (±1°/±2°/±3°/±5°). Dosimetric metrics such as D98% of CTV, and 3D gamma analysis were used to assess the dose distribution changes in the target and OARs. Main results. The magnitudes of dosimetric changes in the targets due to rotational setup error were significantly reduced by the SPArcrot compared to SPArc in all cases. The uncertainties of the max dose to the OARs, such as brainstem, spinal cord and esophagus were significantly reduced using SPArcrot. The uncertainties of the mean dose to the OARs such as liver and oral cavity, parotid were comparable between the two planning techniques. The gamma passing rate (3%/3 mm) was significantly improved for CTV of all tumor sites through SPArcrot. Significance. Rotational setup error is one of the major issues which could lead to significant dose perturbations. SPArcrot planning approach can consider such rotational error from patient setup or gantry rotation error by effectively mitigating the dose uncertainties to the target and in the adjunct series OARs.Keywords
Funding Information
- Ion Beam Application (Industry research grant)
This publication has 45 references indexed in Scilit:
- Range uncertainties in proton therapy and the role of Monte Carlo simulationsPhysics in Medicine & Biology, 2012
- Dosimetric consequences of rotational errors in radiation therapy of pediatric brain tumor patientsRadiotherapy and Oncology, 2012
- Spot Scanning Proton Beam Therapy for Prostate Cancer: Treatment Planning Technique and Analysis of Consequences of Rotational and Translational Alignment ErrorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Intensity-Modulated Proton Therapy Reduces the Dose to Normal Tissue Compared With Intensity-Modulated Radiation Therapy or Passive Scattering Proton Therapy and Enables Individualized Radical Radiotherapy for Extensive Stage IIIB Non-Small-Cell Lung Cancer: A Virtual Clinical StudyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Dosimetric Changes Resulting From Patient Rotational Setup Errors in Proton Therapy Prostate PlansInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Linac-based on-board imaging feasibility and the dosimetric consequences of head roll in head-and-neck IMRT plansMedical Dosimetry, 2008
- Dosimetric effects of patient rotational setup errors on prostate IMRT treatmentsPhysics in Medicine & Biology, 2006
- Multiple regions-of-interest analysis of setup uncertainties for head-and-neck cancer radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Treatment planning and verification of proton therapy using spot scanning: Initial experiencesMedical Physics, 2004
- Radiation therapy oncology group: Radiosurgery quality assurance guidelinesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1993