Postoperative and mid-term wound disturbance outcomes of minimally invasive saphenous vein harvest using the VEGA system
Authors:
- 23 March 2007
- journal article
- research article
- Published by Springer Nature in Heart and Vessels
- Vol. 22 (2) , 94-98
Abstract
Great saphenous vein harvest is associated with a significant risk of impaired wound healing. The purpose of this study was to determine efficacy of one system designed for minimally invasive vein harvest (MIVH) and to assess postoperative and mid-term wound-healing disturbances. From February 2004 to June 2005, great saphenous harvest for coronary artery bypass grafting (CABG) was performed in a group of 120 consecutive patients employing the VEGA system (B/Braun-Aesculap, Tuttlingen, Germany). Patients were evaluated on 7th postoperative day, at the 3-month and 1-year follow-up for wound healing disturbances, residual leg edema, and saphenous neuropathy. The mean age was 67.3 years, male patients dominated (70%), and the leading procedure was CABG (83%). The mean number of harvested venous grafts was 1.9 ± 1.2 and the mean number of skin incisions was 3.7 ± 2.2. The mean total vein harvesting time was 40.2 ± 16.8 minutes. Satisfactory healing was achieved in 98% patients on 7th postoperative day and at the 3-month follow-up all wounds were completely healed. Saphenous neuralgia remained a significant cause of morbidity, although its incidence decreased from 25% presented on 7th postoperative day to 8% presented at 1-year follow-up. Likewise, the incidence of leg edema decreased from 34% on the 7th postoperative day to 7% at 1-year follow-up. Minimally invasive vein harvest is a safe method associated with a significant reduction of wound disturbances. The VEGA system appears to be suitable and effective equipment for MIVH. Nevertheless, residual edema and mainly saphenous neuropathy represent a relatively frequent cause of patient morbidity at the postoperative and mid-term follow-up.Keywords
This publication has 23 references indexed in Scilit:
- Postoperative and Midterm Outcomes of Minimally Invasive and Endoscopic Great Saphenous Vein Harvesting for Coronary Artery Bypass Grafting - A Prospective AnalysisThe Thoracic and Cardiovascular Surgeon, 2007
- Minimally invasive conduit harvesting: a systematic reviewEuropean Journal of Cardio-Thoracic Surgery, 2006
- Endoscopic Vascular Harvest in Coronary Artery Bypass Grafting Surgery: A Consensus Statement of the International Society of Minimally Invasive Cardiothoracic Surgery (ISMICS) 2005Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2005
- Endoscopic Vascular Harvest in Coronary Artery Bypass Grafting Surgery: A Meta-Analysis of Randomized Trials and Controlled TrialsInnovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2005
- Endoscopic saphenous vein harvesting: The good, the bad, and the uglyThe Journal of Thoracic and Cardiovascular Surgery, 2005
- Randomized trial of endoscopic versus open vein harvest for coronary artery bypass grafting: Six-month patency ratesThe Journal of Thoracic and Cardiovascular Surgery, 2005
- Are wound healing disturbances and length of hospital stay reduced with minimally invasive vein harvest? A meta-analysisEuropean Journal of Cardio-Thoracic Surgery, 2004
- Early quantitative coronary angiography of saphenous vein grafts for coronary artery bypass grafting harvested by means of open versus endoscopic saphenectomy: a prospective randomized trialThe Journal of Thoracic and Cardiovascular Surgery, 2004
- Long-term patency of coronary grafts with endoscopically harvested saphenous veins determined by contrast-enhanced electron beam computed tomographyThe Journal of Thoracic and Cardiovascular Surgery, 2004
- Postoperative neuralgia in the leg after saphenous vein coronary artery bypass graft: a prospective study.Thorax, 1988