Comparison between Different Methods for Biomechanical Assessment of Ex Vivo Fracture Callus Stiffness in Small Animal Bone Healing Studies
Open Access
- 17 March 2015
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (3) , e0119603
Abstract
For ex vivo measurements of fracture callus stiffness in small animals, different test methods, such as torsion or bending tests, are established. Each method provides advantages and disadvantages, and it is still debated which of those is most sensitive to experimental conditions (i.e. specimen alignment, directional dependency, asymmetric behavior). The aim of this study was to experimentally compare six different testing methods regarding their robustness against experimental errors. Therefore, standardized specimens were created by selective laser sintering (SLS), mimicking size, directional behavior, and embedding variations of respective rat long bone specimens. For the latter, five different geometries were created which show shifted or tilted specimen alignments. The mechanical tests included three-point bending, four-point bending, cantilever bending, axial compression, constrained torsion, and unconstrained torsion. All three different bending tests showed the same principal behavior. They were highly dependent on the rotational direction of the maximum fracture callus expansion relative to the loading direction (creating experimental errors of more than 60%), however small angular deviations (<15°) were negligible. Differences in the experimental results between the bending tests originate in their respective location of maximal bending moment induction. Compared to four-point bending, three-point bending is easier to apply on small rat and mouse bones under realistic testing conditions and yields robust measurements, provided low variation of the callus shape among the tested specimens. Axial compressive testing was highly sensitive to embedding variations, and therefore cannot be recommended. Although it is experimentally difficult to realize, unconstrained torsion testing was found to be the most robust method, since it was independent of both rotational alignment and embedding uncertainties. Constrained torsional testing showed small errors (up to 16.8%, compared to corresponding alignment under unconstrained torsion) due to a parallel offset between the specimens’ axis of gravity and the torsional axis of rotation.Keywords
This publication has 37 references indexed in Scilit:
- Complement C3 and C5 Deficiency Affects Fracture HealingPLOS ONE, 2013
- Delayed Fracture Healing in Aged Senescence-Accelerated P6 MiceJournal of Investigative Surgery, 2012
- Conversion from external fixator to intramedullary nail causes a second hit and impairs fracture healing in a severe trauma modelJournal of Orthopaedic Research, 2012
- Small animal bone healing models: Standards, tips, and pitfalls results of a consensus meetingBone, 2011
- C5aR‐antagonist significantly reduces the deleterious effect of a blunt chest trauma on fracture healingJournal of Orthopaedic Research, 2011
- Effects of Interleukin‐6 Ablation on Fracture Healing in MiceJournal of Orthopaedic Research, 2011
- Effects of prefracture irradiation on the biomechanical parameters of fracture healingJournal of Orthopaedic Research, 1993
- Geometric, elastic, and structural properties of maturing rat femoraJournal of Orthopaedic Research, 1986
- Mechanical Properties of Fractured and Intact Rat Femora Evaluated by Bending, Torsional and Tensile TestsActa Orthopaedica, 1981
- Methods for Testing the Mechanical Properties of the Rat FemurActa Orthopaedica, 1978