Evaluation of Patient Renal Function Following Endovascular Aneurysm Repair with Suprarenal Fixation
Authors:
Open Access
- 1 April 2011
- journal article
- Published by MDPI AG in Surgical Techniques Development
- Vol. 1 (1) , e10
Abstract
This study aimed to assess the mid-term renal function of abdominal aortic aneurysm patients following suprarenal endovascular repair. From March 2005 to December 2009, 290 abdominal aortic aneurysm patients were included in the study and grouped according to whether they had received infrarenal or suprarenal endovascular aneurysm repair. Suprarenal endovascular aneurysm repair was performed in 173 patients, with a mean age of 72(±8) years (85.0% male). Infrarenal endovascular aneurysm repair was performed in 117 patients, with a mean age of 71(±9) years (90.6% male). Preoperative and one week, 1-, 3-, 6- and 12-month postoperative serum creatinine and cystatin C values were recorded. Estimated glomerular filtration rate was calculated by cystatin-based formula and Cr-based Cockcroft formula. The t-test was used to determine statistical differences between or within groups. All patients received Talent or Zenith endograft. Patients’ characteristics and operative files in the two groups were well matched. Preoperative serum creatinine and cystatin C were 82 (±8) mmol/L and 0.89 (±0.11) mg/L for suprarenal endovascular aneurysm repair, respectively, and 81 (±11) mmol/L and 0.87 (±0.15) mg/L, respectively, for infrarenal endovascular aneurysm repair; no differences were observed between the two groups. Compared to preoperative renal markers within each group, a deterioration in serum creatinine, cystatin C and estimated glomerular filtration rate values was found at one week and 12 months after surgery(p < 0.05). A deterioration in cystatin C [SR:(0.93 ± 0.17) mg/L, IR: (0.92 ± 0.31) mg/L] and estimated glomerular filtration rate by cystatin C was also found at six months after surgery(p < 0.05). However, no differences in patient serum creatinine, cystatin C and estimated glomerular filtration rate values were observed between groups at each follow-up time interval. There was no greater significant difference in the association of the use of suprarenal fixation with midterm postoperative renal injury than with infrarenal fixation.Keywords
This publication has 24 references indexed in Scilit:
- Suprarenal Fixation Barbs Can Induce Renal Artery Occlusion in Endovascular Aortic Aneurysm RepairAnnals of Vascular Surgery, 2010
- Results of Endovascular Repair of Abdominal Aortic Aneurysms with an Unfavorable Proximal Neck Using Large Stent-GraftsCardioVascular and Interventional Radiology, 2009
- Investigation of the Hemodynamic Effect of Stent Wires on Renal Arteries in Patients with Abdominal Aortic Aneurysms Treated with Suprarenal Stent-GraftsCardioVascular and Interventional Radiology, 2009
- Comparative Analysis of Renal Function after Treatment of Infrarenal Abdominal Aortic Aneurysms with a Suprarenal Fixation Device as Opposed to Open SurgeryAnnals of Vascular Surgery, 2008
- Endovascular abdominal aortic aneurysm repair and renal complications: a comparison between suprarenal and infrarenal fixation of stent graftsLa radiologia medica, 2007
- Renal interventions after abdominal aortic aneurysm repair using an aortic endograft with suprarenal fixationThe American Journal of Surgery, 2006
- The Mid-term Effect of Bare Metal Suprarenal Fixation on Renal Function Following Endovascular Abdominal Aortic Aneurysm RepairEuropean Journal of Vascular and Endovascular Surgery, 2006
- Incidence and Effect of Bare Suprarenal Stent Struts Crossing Renal Ostia Following EVAREuropean Journal of Vascular and Endovascular Surgery, 2006
- Assessing the Impact of Renal Impairment on Outcome after Arterial Intervention: A Prospective Review of 1559 PatientsEuropean Journal of Vascular and Endovascular Surgery, 2006
- Suprarenal Endograft Fixation Avoids Adverse Outcomes Associated with Aortic Neck AngulationAnnals of Vascular Surgery, 2005