The Effect of Geometric Variations in Posterior-stabilized Knee Designs on Motion Characteristics Measured in a Knee Loading Machine
Authors:
- Peter S. WalkerPWPeter S. Walker
- Michael T. LowryMLMichael T. Lowry
- Anoop KumarAKAnoop Kumar
- 1 January 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 472 (1) , 238-247
Abstract
Background In different posterior-stabilized (PS) total knees, there are considerable variations in condylar surface radii and cam-post geometry. To what extent these variations affect kinematics is not known. Furthermore, there are no clearly defined ideal kinematics for a total knee. Questions/purposes The purposes of this study were to determine (1) what the kinematic differences are caused by geometrical variations between PS total knee designs in use today; and (2) what design characteristics will produce kinematics that closely resemble that of the normal anatomic knee. Methods Four current PS designs with different geometries and one experimental asymmetric PS design, with a relatively conforming medial side, were tested in a purpose-built machine. The machine applied combinations of compressive, shear, and torque forces at a sequence of flexion angles to represent a range of everyday activities, consistent with the ASTM standard test for measuring constraint. The femorotibial contact points, the neutral path of motion, and the AP and internal-external laxities were used as the kinematic indicators. Results The PS designs showed major differences in motion characteristics among themselves and with motion data from anatomic knees determined in a previous study. Abnormalities in the current designs included symmetric mediolateral motion, susceptibility to excessive AP medial laxity, and reduced laxity in high flexion. The asymmetric-guided motion design alleviated some but not all of the abnormalities. Conclusions Current PS designs showed kinematic abnormalities to a greater or lesser extent. An asymmetric design may provide a path to achieving a closer match to anatomic kinematics. Clinical Relevance One criterion for the evaluation of PS total knees is how closely the kinematics of the prosthesis resemble that of the anatomic knee, because this is likely to affect the quality of function.Keywords
This publication has 30 references indexed in Scilit:
- How Does TKA Kinematics Vary With Transverse Plane Alignment Changes in a Contemporary Implant?Clinical Orthopaedics and Related Research, 2012
- Verification of Predicted Knee Replacement Kinematics During Simulated Gait in the Kansas Knee SimulatorJournal of Biomechanical Engineering, 2010
- Kinematic evaluation of cruciate-retaining total knee replacement patients during level walking: A comparison with the displacement-controlled ISO standardJournal of Biomechanics, 2009
- Total knees designed for normal kinematics evaluated in an up‐and‐down crouching machineJournal of Orthopaedic Research, 2009
- The influence of muscle load on tibiofemoral knee kinematicsJournal of Orthopaedic Research, 2009
- AN ABJS BEST PAPERClinical Orthopaedics and Related Research, 2007
- A direct comparison of patient and force-controlled simulator total knee replacement kinematicsJournal of Biomechanics, 2007
- Anterior tibial post impingement in a posterior stabilized total knee arthroplastyJournal of Orthopaedic Research, 2005
- Measurements of constraint of total knee replacementJournal of Biomechanics, 2005
- Sensitivity of the knee joint kinematics calculation to selection of flexion axesJournal of Biomechanics, 2004