Metrology and methodology of system level ESD testing
Authors:
- D. PommerenkeDPD. Pommerenke
- J. BarthJBJ. Barth
- L.G. HenryLHL.G. Henry
- H. HyattHHH. Hyatt
- M. HopkinsMHM. Hopkins
- G. SenkoGSG. Senko
- D. SmithDSD. Smith
- 27 November 2002
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 29-39
Abstract
Parameters which cause the poor reproducibility of system level ESD tests have been identified: simulator calibration methodology and insufficient simulator specifications. Results of round robin tests performed at three laboratories are reported. A better calibration methodology for ESD current measurement and additional simulator specifications for output current and radiated fields are proposed.Keywords
This publication has 8 references indexed in Scilit:
- Improved statistical method for system-level ESD tests2002
- An analysis of the fields on the horizontal coupling plane in ESD testing1997
- ESD: waveform calculation, field and current of human and simulator ESDJournal of Electrostatics, 1996
- ESD: transient fields, arc simulation and rise time limitJournal of Electrostatics, 1995
- Distortion of Fast Pulses by Non-Tem Effects in Coaxial Cables1995
- Standard probes for electromagnetic field measurementsIEEE Transactions on Antennas and Propagation, 1993
- Fields radiated by electrostatic dischargesIEEE Transactions on Electromagnetic Compatibility, 1991
- A Radiation Measuring System with Potential Automotive Under-Hood ApplicationIEEE Transactions on Electromagnetic Compatibility, 1983