Scale Adjustments to Facilitate Two-Dimensional Measurements in OCT Images
Open Access
- 25 June 2015
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (6) , e0131154
Abstract
To address the problem of unequal scales for the measurement of two-dimensional structures in OCT images, and demonstrate the use of intra¬ocular objects of known dimensions in the murine eye for the equal calibration of axes. The first part of this work describes the mathematical foundation of major distortion effects introduced by X-Y scaling differences. Illustrations were generated with CorelGraph X3 software. The second part bases on image data obtained with a HRA2 Spectralis (Heidelberg Engineering) in SV129 wild-type mice. Subretinally and intravitreally implanted microbeads, alginate capsules with a diameter of 154±5 μm containing GFP-marked mesenchymal stem cells (CellBeads), were used as intraocular objects for calibration. The problems encountered with two-dimensional measurements in cases of unequal scales are demonstrated and an estimation of the resulting errors is provided. Commonly, the Y axis is reliably calibrated using outside standards like histology or manufacturer data. We show here that intraocular objects like dimensionally stable spherical alginate capsules allow for a two-dimensional calibration of the acquired OCT raw images by establishing a relation between X and Y axis data. For our setup, a correction factor of about 3.3 was determined using both epiretinally and subretinally positioned beads (3.350 ± 0.104 and 3.324 ± 0.083, respectively). In this work, we highlight the distortion-related problems in OCT image analysis induced by unequal X and Y scales. As an exemplary case, we provide data for a two-dimensional in vivo OCT image calibration in mice using intraocular alginate capsules. Our results demonstrate the need for a proper two-dimensional calibration of OCT data, and we believe that equal scaling will certainly improve the efficiency of OCT image analysis.Keywords
This publication has 29 references indexed in Scilit:
- Successful Subretinal Delivery and Monitoring of MicroBeads in MicePLOS ONE, 2013
- Influence of Anterior Segment Power on the Scan Path and RNFL Thickness Using SD-OCTInvestigative Ophthalmology & Visual Science, 2012
- Assessing Errors Inherent in OCT-Derived Macular Thickness MapsJournal of Ophthalmology, 2011
- Novel Rodent Models for Macular ResearchPLOS ONE, 2010
- Optimizing Hand-held Spectral Domain Optical Coherence Tomography Imaging for Neonates, Infants, and ChildrenInvestigative Ophthalmology & Visual Science, 2010
- Impact of Scanning Density on Measurements from Spectral Domain Optical Coherence TomographyInvestigative Ophthalmology & Visual Science, 2010
- COMPARISON OF SPECTRAL/FOURIER DOMAIN OPTICAL COHERENCE TOMOGRAPHY INSTRUMENTS FOR ASSESSMENT OF NORMAL MACULAR THICKNESSRetina, 2010
- Spectral Domain Optical Coherence Tomography in Mouse Models of Retinal DegenerationInvestigative Ophthalmology & Visual Science, 2009
- Noninvasive, In Vivo Assessment of Mouse Retinal Structure Using Optical Coherence TomographyPLOS ONE, 2009
- Telomerase expression extends the proliferative life-span and maintains the osteogenic potential of human bone marrow stromal cellsNature Biotechnology, 2002