A biomechanically optimized knitted stent using a bio-inspired design approach
Authors:
- 24 June 2015
- journal article
- research article
- Published by SAGE Publications in Textile Research Journal
- Vol. 86 (4) , 380-392
Abstract
Vascular implants have always been a key area of research in medical textiles. Knitted structures have been proven to be suitable for stent applications on the basis of their looped mesh geometry, structural flexibility and ease of manufacturing. However, there are biomechanical constraints of plain knit constructions that can result in clinical complications after implantation and hence cannot be ignored. This study reports a new segmented knit design inspired by structural metamerism observed in the body design of some invertebrate animals. Metamerism is the phenomenon of having a linear series of body segments fundamentally similar in structure, but assigned to perform different functions. It was hypothesized that utilization of this simple and yet effective biological design approach in stent construction could improve the degree of control for optimizing stent biomechanical properties. The proposed segmented stent was constructed by incorporating an elastic filament component into a polyethylene terephthalate knitted stent at specific intervals along its length, also known as the ‘Plating Technique’. This technique generates a structure with alternately arranged stiff and elastic knitted sections which equip the stent with vital structural support and volumetric compliance properties, respectively. The stent design parameters (filament diameter, loop length, segmentation plan) were optimized to achieve significantly better biomechanical performance (bending flexibility, compression resistance, volumetric expansion, longitudinal extensibility) than a plain knit stent.Keywords
This publication has 31 references indexed in Scilit:
- Development of weft‐knitted and braided polypropylene stents for arterial implantThe Journal of the Textile Institute, 2010
- Effect of abdominal aortic grafts on aortic stiffness and central hemodynamicsJournal Of Hypertension, 2009
- Devices Used for Endovascular Aneurysm Repair: Past, Present, and FutureSeminars in Interventional Radiology, 2009
- Implication of Thoracic Aortic Stent-Graft Conformability on Clinical OutcomesActa Chirurgica Belgica, 2009
- Limb Occlusion after Endovascular Repair of Abdominal Aortic Aneurysms with Supported EndograftsJournal of Vascular and Interventional Radiology, 2008
- A Review of the In Vivo and In Vitro Biomechanical Behavior and Performance of Postoperative Abdominal Aortic Aneurysms and Implanted Stent-GraftsJournal of Endovascular Therapy, 2008
- Evidence suggests rigid aortic grafts increase systolic blood pressure: Results of a preliminary studyMedical Engineering & Physics, 2007
- Effects of compliance mismatch on blood flow in an artery with endovascular prosthesisJournal of Biomechanics, 2005
- New Tubular Bioabsorbable Knitted Airway Stent: Feasibility Assessment for Delivery and Deployment in a Dog ModelThe Annals of Thoracic Surgery, 2004
- Frequency, Predictive Factors, and Consequences of Stent-Graft Kink following Endovascular AAA RepairJournal of Endovascular Therapy, 2003