Active fault tolerant control of CSTR system based on MLD model
Authors:
- 1 May 2014
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3146-3149
Abstract
Predictive control based on mixed logical dynamical (MLD) model can be used as control strategy for hybrid systems effectively. Active fault tolerant control can safeguard the systems running normally, in the case of the damage of the part components in the systems. In this paper, active fault tolerant control based on MLD model is researched with actuator fault. Active fault tolerant control scheme is then applied to a continuous stirred tank reactor (CSTR). Simulation results show the effectiveness of this fault tolerant MPC control.Keywords
This publication has 6 references indexed in Scilit:
- Active fault tolerant control of hybrid system based on MLD model2012
- Static output feedback control for discrete-time switched linear systems under arbitrary switching2009
- Modeling and Control of a Continuous Stirred Tank Reactor Based on a Mixed Logical Dynamical ModelChinese Journal of Chemical Engineering, 2007
- Control of systems integrating logic, dynamics, and constraintsAutomatica, 1999
- Moving horizon estimation for hybrid systems and fault detection1999
- General hybrid dynamical systems: Modeling, analysis, and control1996