Intramuscular Pressure of Tibialis Anterior Reflects Ankle Torque but Does Not Follow Joint Angle-Torque Relationship
Open Access
- 24 January 2018
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 9, 22
Abstract
Intramuscular pressure (IMP) is the hydrostatic fluid pressure that is directly related to muscle force production. Electromechanical delay (EMD) provides a link between mechanical and electrophysiological quantities and IMP has potential to detect local electromechanical changes. The goal of this study was to assess the relationship of IMP with the mechanical and electrical characteristics of the tibialis anterior muscle (TA) activity at different ankle positions. We hypothesized that (1) the TA IMP and the surface EMG (sEMG) and fine-wire EMG (fwEMG) correlate to ankle joint torque, (2) the isometric force of TA increases at increased muscle lengths, which were imposed by a change in ankle angle and IMP follows the length-tension relationship characteristics, and (3) the electromechanical delay (EMD) is greater than the EMD of IMP during isometric contractions. Fourteen healthy adults [7 female; mean (SD) age = 26.9 (4.2) years old with 25.9 (5.5) kg/m2 body mass index] performed (i) three isometric dorsiflexion (DF) maximum voluntary contraction (MVC) and (ii) three isometric DF ramp contractions from 0 to 80% MVC at rate of 15% MVC/second at DF, Neutral, and plantarflexion (PF) positions. Ankle torque, IMP, TA fwEMG, and TA sEMG were measured simultaneously. The IMP, fwEMG, and sEMG were significantly correlated to the ankle torque during ramp contractions at each ankle position tested. This suggests that IMP captures in vivo mechanical properties of active muscles. The ankle torque changed significantly at different ankle positions however, the IMP did not reflect the change. This is explained with the opposing effects of higher compartmental pressure at DF in contrast to the increased force at PF position. Additionally, the onset of IMP activity is found to be significantly earlier than the onset of force which indicates that IMP can be designed to detect muscular changes in the course of neuromuscular diseases impairing electromechanical transmission.Keywords
Funding Information
- Foundation for the National Institutes of Health (R01HD31476, T32-AR056950)
This publication has 51 references indexed in Scilit:
- Muscle shear elastic modulus measured using supersonic shear imaging is highly related to muscle activity levelJournal of Applied Physiology, 2010
- Electromechanical delay revisited using very high frame rate ultrasoundJournal of Applied Physiology, 2009
- The effect of ankle position on intracompartmental pressures of the legActa Orthopaedica et Traumatologica Turcica, 2009
- A COMPARISON OF VOLUNTARY AND INVOLUNTARY MEASURES OF ELECTROMECHANICAL DELAYInternational Journal of Neuroscience, 2007
- Change in Muscle Fascicle Length Influences the Recruitment and Discharge Rate of Motor Units During Isometric ContractionsJournal of Neurophysiology, 2005
- Performance characteristics of a pressure microsensorJournal of Biomechanics, 2003
- Intramuscular pressure and electromyographic responses of the vastus lateralis muscle during repeated maximal isokinetic knee extensionsActa Physiologica Scandinavica, 2000
- Moment arm length variations of selected muscles acting on talocrural and subtalar joints during movement: An In vitro studyJournal of Biomechanics, 1996
- Surface and wire EMG crosstalk in neighbouring musclesJournal of Electromyography and Kinesiology, 1994
- Intramuscular Pressure During WalkingClinical Orthopaedics and Related Research, 1979