Bilateral Macro–Micro Teleoperation Using Magnetic Levitation
Authors:
- 1 June 2011
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 16 (3) , 459-469
Abstract
This paper introduces a novel magnetic-haptic micromanipulation platform with promising potential for extensive biological and biomedical applications. The platform has three basic subsystems: a magnetic untethered microrobotic system, a haptic device, and a scaled bilateral teleoperation system. A mathematical force model of the magnetic propulsion mechanism is developed, and used to design PID controllers for magnetic actuation mechanism. A gain-switching position-position teleoperation scheme is employed for this haptic application. In experimental verifications, a human operator controls the motion of the microrobot via a master manipulator for dexterous micromanipulation tasks. The operator can feel force during microdomain tasks if the microrobot encounters a stiff environment. The effect of hard contact is fed back to the operator's hand in a 20 mm × 20 mm × 30 mm working envelope of the proposed platform. Conducting several experiments under different conditions, rms of position tracking errors varied from 20 to 40 μm.Keywords
This publication has 43 references indexed in Scilit:
- A Self-Sensing Microgripper Module With Wide Handling RangesIEEE/ASME Transactions on Mechatronics, 2010
- Control of a 5DOF Magnetically Levitated Positioning StageIEEE Transactions on Control Systems Technology, 2009
- Three-Dimensional Motion of a Small Object by Using a New Magnetic Levitation System Having Four I-Shaped ElectromagnetsIEEE Transactions on Magnetics, 2008
- Real-Time MRI-Based Control of a Ferromagnetic Core for Endovascular NavigationIEEE Transactions on Biomedical Engineering, 2008
- Six-Axis Magnetic Levitation and Motion ControlIEEE Transactions on Robotics, 2007
- Multiaxis Maglev Positioner With Nanometer Resolution Over Extended Travel RangeJournal of Dynamic Systems, Measurement, and Control, 2007
- Method of Propulsion of a Ferromagnetic Core in the Cardiovascular System Through Magnetic Gradients Generated by an MRI SystemIEEE Transactions on Biomedical Engineering, 2006
- A Gain-Switching Control Scheme for Position-Error-Based Bilateral Teleoperation: Contact Stability Analysis and Controller DesignThe International Journal of Robotics Research, 2004
- Design issues in 2-port network models of bilateral remote manipulation2003
- Stability and transparency in bilateral teleoperationIEEE Transactions on Robotics and Automation, 1993