Influence of uncemented humeral stem proximal geometry on stress distributions and torsional stability following total shoulder arthroplasty
Authors:
- Shoulder Friends InstituteSIShoulder Friends Institute
- Mo SaffariniMSMo Saffarini
Open Access
- 25 February 2019
- journal article
- research article
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 6 (1) , 8
Abstract
While surgeons tend to implant larger stems to improve torsional stability, numerous studies demonstrated that increasing humeral stem diameter could exacerbate stress-shielding and lead to bone resorption. We aimed to determine the influence of humeral stem proximal geometry on stress distributions and torsional stability following total shoulder arthroplasty. Preoperative computed tomography scans were acquired from 5 patients and processed to form 3-dimensional models of the proximal humerus. Computer models of 3 generic implants were created based on three designs: predominantly oval, semi-angular, and predominantly angular. All stems shared identical head geometry and differed only in the proximal metaphyseal area. Finite element analyses were performed, with the humerus rigidly constrained distally, and loaded to simulate the joint reaction force. Implant torsional stability and proximal bone stress distributions were assessed for the three different stem designs with three sizes: oversized (stem making contact with the cortical diaphysis), normosized (one increment smaller) and undersized (two increments smaller). Considering the normosized stems, the angular design increased the physiologic bone stresses at the proximal section by 39–42%, while the oval and semi-angular designs reduced them by 5–9% and 8–13%, respectively. The oval design exhibited a median rotation of 2.1°, while the semi-angular and angular designs exhibited median rotations of 1.8°. The semi-angular stem granted an adequate compromise between physiologic stress distributed by the oval stem and torsional stability of the angular stem. Surgeons should be aware of the various benefits and drawbacks of the different humeral stem designs to ensure adequate torsional stability and physiologic loading.Keywords
This publication has 33 references indexed in Scilit:
- Age and gender as determinants of the bone quality of the greater tuberosity: A HR-pQCT cadaver studyBMC Musculoskeletal Disorders, 2012
- Bone remodelling analysis of the humerus after a shoulder arthroplastyMedical Engineering & Physics, 2012
- Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitroJournal of Biomechanics, 2008
- Long-term results of uncemented humeral components in shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2007
- Artificial composite bone as a model of human trabecular bone: The implant–bone interfaceJournal of Biomechanics, 2007
- Subject-specific finite element models of long bones: An in vitro evaluation of the overall accuracyJournal of Biomechanics, 2006
- Prosthetic positioning in total shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2005
- Trabecular bone modulus–density relationships depend on anatomic siteJournal of Biomechanics, 2003
- Friction and stem stiffness affect dynamic interface motion in total hip replacementJournal of Orthopaedic Research, 1996
- Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurementsJournal of Biomechanics, 1993