Mechanical resistance of screwless morse taper and screw‐retained implant‐abutment connections
- 9 December 2013
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 26 (2) , 137-142
Abstract
Objective The screwless morse taper (SMT) implant‐abutment connection is an alternative to conventional external or internal screw‐retained (ISR) connections. The aim of this in vitro study was to evaluate mechanical resistance of the SMT connection and to compare it with three different ISR connections. Materials and Methods Four implant systems were tested in this study: SMT system; Tasarimmed Octo (Istanbul, Turkey), ISR systems; Straumann Bone Level (Basel, Switzerland), Biohorizons Internal (Birmingham, AL, USA), and Dentsply Friadent Xive (Mannheim, Germany). Overall, 64 specimens with stylized single crowns were prepared: 32 for dynamic loading (DL) and 32 for static loading (SL). DL was carried out using a chewing simulator with 120 N at 1.75 Hz for 1.2 × 106 cycles, and SL was performed with a universal testing machine at a crosshead speed of 2 mm/min with an angulation of 30°. Cycles until failure from DL and fracture/bending loads at SL were recorded. Statistical analyses were made with Dunn's multiple comparison. Results Median cycles until failure in DL were as follows: Octo 86,354 (24,810–153,875), Straumann 1,200,000 (1,156,618–1,200,000), Biohorizons 539,719 (437,224–858,732), Xive 139,411 (139,411–139,411). Median fracture/bending loads in Newton at SL were as follows: Octo 429.6 (404.5–482.7), Straumann 574.6 (544.6–629.9), Biohorizons 548.7 (532.9–567.3), Xive 431.5 (412.5–520.5). There were significant differences between the implant systems under both loading conditions (P ≤ 0.05) revealing that the Octo implant system's SMT connection showed significantly lower cycles to failures and lower fracture/bending loads compared with the ISR connections of the Straumann and Biohorizons implant systems. However, there was no significant difference compared with the Xive implant system. Conclusion The mechanical resistance of the screwless morse taper implant system is lower than that of the ISR implant systems that might result in more frequent clinical complications.Keywords
This publication has 28 references indexed in Scilit:
- Implants (3.3 mm Diameter) for the Rehabilitation of Edentulous Posterior Regions: A Retrospective Clinical Study with Up to 11 Years of Follow‐UpClinical Implant Dentistry and Related Research, 2011
- Prospective Evaluation of 2,549 Morse Taper Connection Implants: 1‐ to 6‐Year DataJournal of Periodontology, 2011
- Effects of Abutment Screw Coating on Implant PreloadJournal of Prosthodontics, 2010
- Evaluation of 316 narrow diameter implants followed for 5–10 years: a clinical and radiographic retrospective studyClinical Oral Implants Research, 2010
- Sinking and fit of abutment of locking taper implant systemThe Journal of Advanced Prosthodontics, 2009
- Technical complications of implant‐supported fixed partial dentures in partially edentulous cases after an average observation period of 5 yearsClinical Oral Implants Research, 2007
- The regulation of masticatory function and food bolus formationJournal of Oral Rehabilitation, 2006
- A prospective clinical evaluation of different single‐tooth restoration designs on osseointegrated implants. A 3‐year follow‐up of Brånemark implants.Clinical Oral Implants Research, 1999
- Long‐term evaluation of non‐submerged ITI implants. Part 1: 8‐year life table analysis of a prospective multi‐center study with 2359 implants.Clinical Oral Implants Research, 1997
- The elastic moduli of human subchondral, trabecular, and cortical bone tissue and the size-dependency of cortical bone modulusJournal of Biomechanics, 1990