Abstract
Orifice spillways are in vogue for the dams in the hilly regions where the spillway has to serve the dual function of flood disposal and flushing of sediment through the reservoir. Deep-seated orifice spillways are subjected to cavitation damage as the cavitation index drops below the critical cavitation index of 0.2 because of negative pressures on the profile and high flow velocities. Aerators are provided for mitigating cavitation damage. Design guidelines for aerator of orifice spillways are scanty and not reported much in the literature so far; thus, there still remains gray area in the field of spillway aerator design. The present study investigates the performance of an offset aerator with and without a ramp for deep-seated orifice spillway on a physical and numerical model. Performance of the aerator for varying discharges, heads, and gate openings is studied for varying cavity subpressures. Results with respect to jet length, cavity subpressure and air entrainment coefficients are present...

This publication has 1 reference indexed in Scilit: