Mitral valve flattening and parameter mapping for patient-specific valve diagnosis
Open Access
- 18 January 2020
- journal article
- research article
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 15 (4) , 617-627
Abstract
Purpose: Intensive planning and analysis from echocardiography are a crucial step before reconstructive surgeries are applied to malfunctioning mitral valves. Volume visualizations of echocardiographic data are often used in clinical routine. However, they lack a clear visualization of the crucial factors for decision making. Methods: We build upon patient-specific mitral valve surface models segmented from echocardiography that represent the valve’s geometry, but suffer from self-occlusions due to complex 3D shape. We transfer these to 2D maps by unfolding their geometry, resulting in a novel 2D representation that maintains anatomical resemblance to the 3D geometry. It can be visualized together with color mappings and presented to physicians to diagnose the pathology in one gaze without the need for further scene interaction. Furthermore, it facilitates the computation of a Pathology Score, which can be used for diagnosis support. Results: Quality and effectiveness of the proposed methods were evaluated through a user survey conducted with domain experts. We assessed pathology detection accuracy using 3D valve models in comparison with the novel visualizations. Classification accuracy increased by 5.3% across all tested valves and by 10.0% for prolapsed valves. Further, the participants’ understanding of the relation between 3D and 2D views was evaluated. The Pathology Score is found to have potential to support discriminating pathologic valves from normal valves. Conclusions: In summary, our survey shows that pathology detection can be improved in comparison with simple 3D surface visualizations of the mitral valve. The correspondence between the 2D and 3D representations is comprehensible, and color-coded pathophysiological magnitudes further support the clinical assessment.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (EN1197/2-1)
- Deutsche Forschungsgemeinschaft (DE 2131/2-1)
- Deutsche Forschungsgesellschaft (LA 3855/1-1)
This publication has 18 references indexed in Scilit:
- Intraoperative Quantitative Mitral Valve Analysis Using Optical Tracking TechnologyThe Annals of Thoracic Surgery, 2016
- Personalized Computational Modeling of Mitral Valve Prolapse: Virtual Leaflet ResectionPLOS ONE, 2015
- Towards Automatic Assessment of the Mitral Valve Coaptation Zone from 4D Ultrasound2015
- Stent Maps — Comparative Visualization for the Prediction of Adverse Events of Transcatheter Aortic Valve ImplantationsIEEE Transactions on Visualization and Computer Graphics, 2014
- Effect of leaflet-to-chordae contact interaction on computational mitral valve evaluationBioMedical Engineering OnLine, 2014
- The effect of pure mitral regurgitation on mitral annular geometry and three-dimensional saddle shapeThe Journal of Thoracic and Cardiovascular Surgery, 2008
- Image-based mass-spring model of mitral valve closure for surgical planning2008
- Periodic global parameterizationACM Transactions on Graphics, 2006
- Interactive texture mapping1993
- Piecewise surface flattening for non-distorted texture mappingACM SIGGRAPH Computer Graphics, 1991