Abstract
Objective Vein of Galen malformation (VGAM) in neonates presents a complex management challenge. Measurement of superior vena cava (SVC) blood flow may provide insights into the haemodynamics of VGAM and the effects of therapeutic intervention. Methods SVC flow was assessed in 15 neonates with VGAM. SVC flow results, Bicêtre scores (clinical assessment), echocardiographic assessment and clinical outcomes are presented. Results SVC flows (166–581 ml/kg/min) were significantly elevated at presentation (p400 ml/kg/min (n=5) had an adverse outcome (death or profound neurological damage). Cases with SVC flow Conclusions SVC flow measurements provide insight into the haemodynamic challenges of VGAM and provide additional useful prognostic information.