Novel application of Poincaré analysis to detect and quantify exercise oscillatory ventilation
Authors:
- 1 April 2021
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 42 (4) , 04NT01
Abstract
Objective. Exercise oscillatory ventilation (EOV) is frequently observed in individuals with cardiac disease. Assessment of EOV relies on pattern recognition and this subjectivity and lack of quantification limits the widespread clinical use of EOV as a prognostic marker. Poincaré analysis quantifies the short (SD1) and long-term (SD2) variability of a signal and may provide an alternative means to identify and quantify unstable exercise breathing patterns. This study aimed to determine if Poincaré analysis can distinguish between the breathing patterns of healthy control subjects and individuals being assessed for heart transplantation with and without EOV. Approach. Thirty-nine subjects performed a cardiopulmonary exercise test as part of heart transplant assessment and were subjectively classified into two groups according to the presence of EOV: non-EOV ( n = 19) and EOV ( n = 20). The control group ( n = 24) consisted of healthy adults. Poincaré analysis (SD1 and SD2) was performed for minute ventilation ( V ̇ E ) and tidal volume (VT) normalized to forced vital capacity ( V ̇ E n and V ̇ T n ), and breathing frequency (BF) for breath-by-breath data over the 10–15 ml · min −1 · kg −1 V ̇ O 2 range. Main results. Poincaré analysis showed similar exercise ventilatory responses between the non-EOV and control group. BF was found to discriminate between subjects with stable and unstable ventilation. BF SD1 was significantly higher in the EOV group compared to the non-EOV (7.9 versus 4.6, p < 0.01) and control (7.9 versus 4.2, p < 0.01) groups. The EOV group had significantly greater BF SD2 compared to the non-EOV (5.7 versus 3.5, p < 0.01) and control (5.7 versus 3.5, p < 0.01) groups. Significance. We demonstrated that this novel application of Poincaré analysis can objectively distinguish and quantify unstable from stable breathing patterns during exercise. In subjects being assessed for heart transplantation the presence of EOV is associated with greater BF variability. Poincaré analysis provides an objective measure to identify and quantify EOV. Summary at a glance. As EOV may indicate abnormal ventilatory control, there is a need for an objective measure to identify and quantify unstable from stable ventilation during exercise. We developed a method of quantifying BF variation by the application of Poincaré analysis and demonstrated higher than normal variability of BF in subjects being assessed for heart transplantation who demonstrated EOV.Keywords
This publication has 26 references indexed in Scilit:
- Minute-Ventilation Variability during Cardiopulmonary Exercise Test is Higher in Sedentary Men Than in AthletesArquivos Brasileiros de Cardiologia, 2017
- An overview of the applied definitions and diagnostic methods to assess exercise oscillatory ventilation — A systematic reviewInternational Journal of Cardiology, 2015
- Clinical Recommendations for Cardiopulmonary Exercise Testing Data Assessment in Specific Patient PopulationsCirculation, 2012
- Exercise oscillatory ventilation reflects diminished quality of life and perceived functional capacity in patients with heart failureInternational Journal of Cardiology, 2011
- Ventilation variability inversely correlates to ejection fraction in heart failure: Table 1–European Respiratory Journal, 2010
- Clinician’s Guide to Cardiopulmonary Exercise Testing in AdultsCirculation, 2010
- Prognostic Value of Timing and Duration Characteristics of Exercise Oscillatory Ventilation in Patients With Heart FailureThe Journal of Heart and Lung Transplantation, 2008
- Breathing pattern variability: a weaning predictor in postoperative patients recovering from systemic inflammatory response syndromeIntensive Care Medicine, 2004
- Exercise-Induced Pulmonary Edema in Heart FailureCirculation, 2003
- Do existing measures of Poincare plot geometry reflect nonlinear features of heart rate variability?IEEE Transactions on Biomedical Engineering, 2001