Multidimensional Tracing of Error Sources and Structured Corrective Strategies for Leukocyte Count and Differential on Automated Hematology Analyzers
Open Access
- 29 October 2026
- journal article
- review article
- Published by MDPI AG in Diagnostics
- Vol. 16 (21) , 3578
Abstract
Leukocyte count and differential are core indicators for clinical infection assessment, hematological disease diagnosis, and therapeutic monitoring. Currently, clinical testing heavily relies on automated hematology analyzers. Influenced by factors such as specimen characteristics, limited analyzer recognition capability, and improper manual operations, automated testing often produces unreliable results, interfering with clinical decision-making and threatening patient safety. Existing studies remain fragmented, lacking a multidimensional error-tracing framework and practical corrective strategies covering the entire testing workflow. A narrative review was conducted to summarize the causes, identification methods, and corrective strategies for unreliable leukocyte results. Relevant literature up to August 2026 was searched in PubMed/MEDLINE and CNKI. We categorized multidimensional error sources into specimen-related interferents, leukocyte morphological and developmental abnormalities, and preanalytical or systematic factors, and established a practical diagnostic workflow spanning from anomaly recognition to result reporting. By incorporating both legacy and current analytical systems, we compared the characteristic scattergram patterns of various interferents across analyzers with different detection principles, broadening the applicability to diverse clinical laboratories. To better ensure the reliability of corrective strategies and provide diverse alternative options, we not only summarized widely accepted routine practices but also included case-based experimental methods. The proposed multidimensional error-tracing system and practical diagnostic workflow significantly improve analytical accuracy and reduce clinical risks. However, current hematology analyzers cannot automatically identify or correct complex interferences. Future systems must integrate multi-platform advantages, optimize complex cell recognition capabilities, and enrich multidimensional scattergram information to overcome existing analytical limitations. Furthermore, integrating artificial intelligence technology holds immense potential to drive automated hematology analysis toward a more intelligent and precise direction.Keywords
Funding Information
- Peking Union Medical College Hospital (2026-PUMCH-H-007)
This publication has 97 references indexed in Scilit:
- Advantages of AI-based whole blood film scanning for blast detection in markedly leucopenic blood filmsAnnals of Hematology, 2025
- The dilution evaluation as a corrective measure for interference in the white blood cell scattergram in Beckman Coulter DxH 900Journal of Clinical Laboratory Analysis, 2024
- Another cause of pseudobasophilia: flower cellsJournal of Hematopathology, 2023
- Spurious Leukocyte Counts and an Abnormal Histogram Pattern Due to Fibrin ClumpsIndian Journal of Hematology and Blood Transfusion, 2018
- Cold-Induced Pseudoneutropenia in Human Immunodeficiency Virus Infection: First Case Report and Review of Related ArticlesIndian Journal of Hematology and Blood Transfusion, 2013
- A Simple, Fast Correction Method of Triglyceride Interference in Blood Hemoglobin Automated MeasurementJournal of Clinical Laboratory Analysis, 2013
- Effects of bacteria and yeast on WBC counting in three automated hematology countersAnnals of Hematology, 2008
- Pseudoeosinophilia associated with malaria infection determined in the Sysmex XE-2100 hematology analyzerAnnals of Hematology, 2004
- Spurious leukocytosis‐simulating relapse of chronic myeloid leukemia after bone marrow transplant: Possible relationship to hypercholesterolemia and hyperbiliru binemiaAmerican Journal of Hematology, 1995
- Spurious leukocytosis and thrombocytopenia. A dual phenomenon caused by clumping of platelets in vitro1983