Abstract
A novel fault-tolerant inverter topology of the multi-port dual-stator doubly salient electromagnetic machine (MDDSEM) drive is proposed in this paper for high reliability applications such as automotive and aerospace industries. The proposed topology adopts four diverter switches to reconnect the floating phase windings under the fault conditions, and reconfigures the dual-inverter to be a five-leg inverter, the output performance could be maintained after single phase open-circuit or short-circuit fault of the dual-inverter. Compared with the traditional fault tolerant method of dual-inverter for the MDDSEM, the lower cost and smaller volume of the proposed fault tolerant system can be achieved. The operation principle and optimized commutation method of the five-leg inverter for MDDSEM is analyzed to eliminate the unexpected phase current drop so that the torque performance in the fault-tolerant mode could be improved. The effectiveness and feasibility of the proposed fault-tolerant topology and control strategies are verified by the simulation and experimental results of a 24/16 MDDSEM that includes both steady state and dynamic process with standard angle control method and advanced angle control method.
Funding Information
  • State Key Program of National Nature Science Foundation of China (51737006)
  • National Natural Science Foundation of China (51477075)
  • Fundamental Research Funds for the Central Universities (NS2016033)

This publication has 15 references indexed in Scilit: