An extended vascular model for less biased estimation of permeability parameters in DCE‐T1 images
- 17 February 2017
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 30 (6)
Abstract
One of the key elements in dynamic contrast enhanced (DCE) image analysis is the arterial input function (AIF). Traditionally, in DCE studies a global AIF sampled from a major artery or vein is used to estimate the vascular permeability parameters; however, not addressing dispersion and delay of the AIF at the tissue level can lead to biased estimates of these parameters. To find less biased estimates of vascular permeability parameters, a vascular model of the cerebral vascular system is proposed that considers effects of dispersion of the AIF in the vessel branches, as well as extravasation of the contrast agent (CA) to the extravascular‐extracellular space. Profiles of the CA concentration were simulated for different branching levels of the vascular structure, combined with the effects of vascular leakage. To estimate the permeability parameters, the extended model was applied to these simulated signals and also to DCE‐T1 (dynamic contrast enhanced T1) images of patients with glioblastoma multiforme tumors. The simulation study showed that, compared with the case of solving the pharmacokinetic equation with a global AIF, using the local AIF that is corrected by the vascular model can give less biased estimates of the permeability parameters (Ktrans, vp and Kb). Applying the extended model to signals sampled from different areas of the DCE‐T1 image showed that it is able to explain the CA concentration profile in both the normal areas and the tumor area, where effects of vascular leakage exist. Differences in the values of the permeability parameters estimated in these images using the local and global AIFs followed the same trend as the simulation study. These results demonstrate that the vascular model can be a useful tool for obtaining more accurate estimation of parameters in DCE studies.Keywords
Funding Information
- National Institutes of Health (RO1NS64134)
This publication has 24 references indexed in Scilit:
- A parametric model of the brain vascular system for estimation of the arterial input function (AIF) at the tissue levelNMR in Biomedicine, 2017
- Blood Tracer Kinetics in the Arterial TreePLOS ONE, 2014
- Arterial input function in perfusion MRI: A comprehensive reviewProgress in Nuclear Magnetic Resonance Spectroscopy, 2013
- Classic models for dynamic contrast‐enhanced MRINMR in Biomedicine, 2013
- Estudio de la perfusión cerebral mediante técnicas de susceptibilidad magnética: técnica y aplicacionesRadiologia, 2012
- Model selection for DCE‐T1 studies in glioblastomaMagnetic Resonance in Medicine, 2011
- Quantification of cerebral blood flow, cerebral blood volume, and blood–brain‐barrier leakage with DCE‐MRIMagnetic Resonance in Medicine, 2009
- Whole-body physiologically based pharmacokinetic modelsExpert Opinion on Drug Metabolism & Toxicology, 2007
- Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decompositionMagnetic Resonance in Medicine, 2000
- Estimating kinetic parameters from dynamic contrast-enhanced t1-weighted MRI of a diffusable tracer: Standardized quantities and symbolsJournal of Magnetic Resonance Imaging, 1999