Electrode position, distance, size, and orientation determine efficacy of cervical epidural stimulation to recruit forelimb muscles in rats
Preprint
Abstract
Target engagement determines therapeutic efficacy. In spinal cord stimulation (SCS), efficacy depends on the attributes of the electrodes used to deliver stimulation, particularly their position, interelectrode distance, size, and current orientation. We tested the effects of these electrode parameters using cervical stimulation to elicit forelimb muscle responses in the rat. We implanted devices over the C6 dorsal root entry zone (DREZ) in eight rats and measured responses in six forelimb muscles. We used custom designed electrode arrays to systematically vary position, distance, and size with linear arrays, and current orientation with circular arrays. Stimulation consisted of biphasic and pseudomonophasic pulse shapes with bipolar or distant return, and a high-definition montage with four returns surrounding a central contact to increase local current density. Efficacy was calculated from the motor thresholds of recruitment curves, and parameters were compared using linear mixed models. For position, stimulation over the DREZ was most effective, reducing thresholds by 25.9% ( p = 0.0002) relative to the midline; efficacy decreased as the electrode was positioned medial or lateral to the DREZ. For distance, placing the electrodes farther apart significantly improved efficacy ( p = 0.0022). For size, large electrodes increased SCS efficacy, reducing thresholds by 21.5% ( p = 0.0026) relative to small electrodes. After accounting for position and distance, current orientation did not affect SCS efficacy. Lastly, the high-definition montage decreased efficacy, increasing thresholds by 16.7% ( p = 0.003) relative to monopolar stimulation with a distant return. In conclusion, electrode position, distance, and size had the greatest effect on SCS efficacy, with the optimal parameters combining large electrodes at the DREZ position with a distant return. These results have the potential to lower the current needed to engage cervical spinal circuitry and to inform the design of SCS systems to improve dexterity in people with neurological injury or disease.Keywords
Funding Information
- National Institute of Neurological Disorders and Stroke (R01NS124224)
- National Institute of Neurological Disorders and Stroke (1R03NS141040)
- New York State Department of Health (C38336GG)
This publication has 50 references indexed in Scilit:
- Stimulation of the Human Lumbar Spinal Cord With Implanted and Surface Electrodes: A Computer Simulation StudyIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2010
- Gyri-precise head model of transcranial direct current stimulation: Improved spatial focality using a ring electrode versus conventional rectangular padBrain Stimulation, 2009
- Transcranial current stimulation focality using disc and ring electrode configurations: FEM analysisJournal of Neural Engineering, 2008
- A lithographically-patterned, elastic multi-electrode array for surface stimulation of the spinal cordBiomedical Microdevices, 2007
- Spinal Cord Stimulation Electrode Design: A Prospective, Randomized, Controlled Trial Comparing Percutaneous with Laminectomy Electrodes: Part II–Clinical OutcomesNeurosurgery, 2005
- Spinal cord stimulation electrode design: prospective, randomized, controlled trial comparing percutaneous and laminectomy electrodes-part I: technical outcomes.2002
- Epidural electrical stimulation of posterior structures of the human lumbosacral cord: 2. quantitative analysis by computer modelingSpinal Cord, 2000
- Effects of electrode geometry and combination on nerve fibre selectivity in spinal cord stimulationMedical & Biological Engineering & Computing, 1995
- Excitation of dorsal root fibers in spinal cord stimulation: a theoretical studyIEEE Transactions on Biomedical Engineering, 1993
- The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologistMedical & Biological Engineering & Computing, 1967