Preliminary validation and performance of the Jason microwave radiometer
Authors:
- S. BrownSBS. Brown
- C. RufCRC. Ruf
- S. KeihmSKS. Keihm
- A. KitiyakaraAKA. Kitiyakara
- 25 May 2004
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1077-1079
Abstract
The Jason Microwave Radiometer is calibrated using hot and cold on-Earth theoretical brightness temperature references. The retrieved path delay values are validated using co-located Topex Microwave Radiometer and radiosonde values. The calibrated path delay values are demonstrated to have no significant bias or scale errors. The absolute accuracy of the individual path delay measurements exceeds the mission goal of 1.2 cm RMS.Keywords
This publication has 5 references indexed in Scilit:
- TOPEX microwave radiometer performance evaluation, 1992-1998IEEE Transactions on Geoscience and Remote Sensing, 2000
- Detection of calibration drifts in spaceborne microwave radiometers using a vicarious cold referenceIEEE Transactions on Geoscience and Remote Sensing, 2000
- TOPEX/Poseidon microwave radiometer (TMR). III. Wet troposphere range correction algorithm and pre-launch error budgetIEEE Transactions on Geoscience and Remote Sensing, 1995
- TOPEX/POSEIDON microwave radiometer performance and in‐flight calibrationJournal of Geophysical Research: Oceans, 1994
- Equations for Calculating the Dielectric Constant of Saline Water (Correspondence)IEEE Transactions on Microwave Theory and Techniques, 1971