Shielding Benchmark Calculations with SCALE/MAVRIC and Comparison with Measurements for the German Cask CASTOR® HAW 20/28 CG
Authors:
- 1 December 2009
- journal article
- research article
- Published by Taylor & Francis in Nuclear Technology
- Vol. 168 (3) , 867-870
Abstract
The purpose of this research was to make shielding benchmark calculations with the new Standardized Computer Analyses for Licensing Evaluation (SCALE) shielding sequence Monaco with Automated Variance Reduction Importance Calculations (MAVRIC) and compare with SCALE SAS4/MORSE calculations as well as dose rate measurements for the German storage/transport cask CASTOR® high active waste (HAW) 20/28 CG. MAVRIC with improved transport methodology is the successor of SAS4 and was released as part of SCALE version 6 in 2009. The new calculations with MAVRIC resolve discrepancies of results obtained with SAS4 in comparison to measured data. Cask areas with heterogeneous structures like trunnions and ducts are of special interest.Based on dose rate measurements for neutron and gamma radiation on a CASTOR® HAW 20/28 CG cask and to extend our own shielding calculations done with the SCALE SAS4/MORSE sequence, the new SCALE shielding sequence MAVRIC/Monaco has been used for comprehensive calculations to tre...Keywords
This publication has 1 reference indexed in Scilit:
- Comparison of dose rate calculations with measurements at CASTOR HAW 20/28 CG caskPackaging, Transport, Storage & Security of Radioactive Material, 2006