Estimation of three‐dimensional intrinsic dosimetric uncertainties resulting from using deformable image registration for dose mapping
- 21 December 2010
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 38 (1) , 343-353
Abstract
Purpose: This article presents a general procedural framework to assess the point‐by‐point precision in mapped dose associated with the intrinsic uncertainty of a deformable image registration (DIR) for any arbitrary patient.Methods: Dose uncertainty is obtained via a three‐step process. In the first step, for each voxel in an imaging pair, a cluster of points is obtained by an iterative DIR procedure. In the second step, the dispersion of the points due to the imprecision of the DIR method is used to compute the spatial uncertainty. Two different ways to quantify the spatial uncertainty are presented in this work. Method A consists of a one‐dimensional analysis of the modules of the position vectors, whereas method B performs a more detailed 3D analysis of the coordinates of the points. In the third step, the resulting spatial uncertainty estimates are used in combination with the mapped dose distribution to compute the point‐by‐point dose standard deviation. The process is demonstrated to estimate the dose uncertainty induced by mapping a 62.6 Gy dose delivered on maximum exhale to maximum inhale of a ten‐phase four‐dimensional lung CT.Results: For the demonstration lung image pair, the standard deviation of inconsistency vectors is found to be up to 9.2 mm with a mean of 1.3 mm. This uncertainty results in a maximum estimated dose uncertainty of 29.65 Gy if method A is used and 21.81 Gy for method B. The calculated volume with dose uncertainty above 10.00 Gy is for method A and for method B.Conclusions: This procedure represents a useful tool to evaluate the precision of a mapped dose distribution due to the intrinsic DIR uncertainty in a patient. The procedure is flexible, allowing incorporation of alternative intrinsic error models.Keywords
Funding Information
- National Institutes of Health (NIH-P01-CA116602)
This publication has 27 references indexed in Scilit:
- Results of a Multi-Institution Deformable Registration Accuracy Study (MIDRAS)International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Symmetric inverse consistent nonlinear registration driven by mutual informationComputer Methods and Programs in Biomedicine, 2009
- The utilization of consistency metrics for error analysis in deformable image registrationPhysics in Medicine & Biology, 2009
- A framework for evaluation of deformable image registration spatial accuracy using large landmark point setsPhysics in Medicine & Biology, 2009
- Objective assessment of deformable image registration in radiotherapy: A multi‐institution studyMedical Physics, 2008
- FEM-based evaluation of deformable image registration for radiation therapyPhysics in Medicine & Biology, 2007
- Does elastic tissue intrafraction motion with density changes forbid motion-compensated radiotherapy?Physics in Medicine & Biology, 2006
- Consistent landmark and intensity-based image registrationIEEE Transactions on Medical Imaging, 2002
- Consistent image registrationIEEE Transactions on Medical Imaging, 2001
- Deformable templates using large deformation kinematicsIEEE Transactions on Image Processing, 1996