Contrast-enhanced Ultrasound Using Intradermal Microbubble Sulfur Hexafluoride for Identification of Sentinel Lymph Nodes During Breast Cancer Surgery: A Clinical Trial
Open Access
- 25 January 2023
- journal article
- research article
- Published by International Institute of Anticancer Research in Anticancer Research
- Vol. 43 (2) , 557-567
Abstract
Background/Aim: Sentinel lymph node (SLN) procedures have gained popularity in early breast cancer thanks to the reduction of surgical side-effects. The standard SLN mapping procedure uses 99mTc-nanocolloid human serum albumin with/without blue dye; limitations include logistical challenges and adverse reactions. Recently, contrast-enhanced ultrasound (CEUS) using sulfur hexafluoride has emerged as a promising technique for SLN mapping. Our study aimed to compare the CEUS technique with the standard isotope method. Materials and Methods: AX-CES, a prospective, monocentric, single-arm phase-3 study was designed (EudraCT: 2020-000393-20). Inclusion criteria were histologically diagnosed early breast cancer eligible for upfront surgery and SLN resection, bodyweight 40-85 kg, and no prior history of ipsilateral surgery or radiotherapy. All patients underwent CEUS prior to surgery and blue dye injection was performed in areas with contrast accumulation. After the experimental procedure, all patients underwent the standard mapping procedure and SLN frozen section assessment was performed. Data on the success rate, systemic reactions, mean procedure time, CEUS appearance, SLN number, and concordance with standard mapping procedure were collected. Results: Among 16 cases, a median of two SLNs were identified during CEUS. In all cases, at least one SLN was identified by CEUS (100%). In six cases, SLNs were classified during CEUS as abnormal, which was confirmed by definitive staining in four cases. After the standard mapping technique, in 15 out of the 16 cases (87.50%), at least one SLN from the standard mapping procedure was marked with blue dye in the CEUS procedure. In our series, sensitivity and specificity of SLN detection by CEUS were 75% and 100%, respectively. Conclusion: CEUS is a safe and manageable intraoperative procedure. When compared with standard techniques, US appearance during CEUS may provide additional information when associated with histological assessment.Keywords
This publication has 62 references indexed in Scilit:
- False Negative Rate of Sentinel Lymph Node Biopsy on Intraoperative Frozen Section in Early Breast Cancer Patients: An Institutional ExperienceIndian Journal of Surgical Oncology, 2021
- Factors affecting the number of sentinel lymph nodes removed in patients having surgery for breast cancerBreast Cancer Research and Treatment, 2020
- Sentinel lymph node biopsy without axillary lymphadenectomy after neoadjuvant chemotherapy is accurate and safe for selected patients: the GANEA 2 studyBreast Cancer Research and Treatment, 2018
- Feasibility of using negative ultrasonography results of axillary lymph nodes to predict sentinel lymph node metastasis in breast cancer patientsCancer Medicine, 2018
- Effect of Axillary Dissection vs No Axillary Dissection on 10-Year Overall Survival Among Women With Invasive Breast Cancer and Sentinel Node MetastasisJAMA, 2017
- Identification of sentinel lymph nodes by contrast‐enhanced ultrasonography with Sonazoid in patients with breast cancer: a feasibility study in three hospitalsCancer Medicine, 2017
- Intra-operative ultrasound versus wire-guided localization in the surgical management of non-palpable breast cancers: systematic review and meta-analysisBreast Cancer Research and Treatment, 2013
- Decreasing incidence of late‐stage breast cancer after the introduction of organized mammography screening in ItalyCancer, 2013
- Factors affecting failed localisation and false-negative rates of sentinel node biopsy in breast cancer – results of the ALMANAC validation phaseBreast Cancer Research and Treatment, 2006
- Lymphatic mapping and sentinel lymph node biopsy in early‐stage breast carcinomaCancer, 2005