Diagnosis of Obstructive Sleep Apnea Using Pulse Oximeter Derived Photoplethysmographic Signals
- 15 March 2014
- journal article
- clinical trial
- Published by Springer Nature in Journal of Clinical Sleep Medicine
- Vol. 10 (3) , 285-290
Abstract
Increasing awareness of the high prevalence of obstructive sleep apnea (OSA) and its impact on health in conjunction with high cost, inconvenience, and short supply of in-lab polysomnography (PSG) has led to the development of more convenient, affordable, and accessible diagnostic devices. We evaluated the reliability and accuracy of a single-channel (finger pulse-oximetry) photoplethysmography (PPG)-based device for detection of OSA (Morpheus Ox). Among a cohort of 73 patients referred for in-laboratory evaluation of OSA, 65 were simultaneously monitored with the PPG based device while undergoing PSG. Among these, 19 had significant cardiopulmonary comorbidities. Using the PSG as the "gold standard," the sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), as well as the positive likelihood ratio (+LR) for an apnea hypopnea index (AHI)PSG > 5/h and AHIPSG > 15/h were calculated for the PPG. Valid results were available for 65 subjects. Mean age: 52.1 ± 14.2, Male: 52%, and BMI: 36.3 ± 9.7 kg/m(2). Positive correlation was found between PPG-derived and PSG-derived AHI (r = 0.81, p < 0.001). For AHIPSG > 5/h, sensitivity was 80%, specificity 86%, PPV 93%, NPV 68%, and +LR was 5.9. For AHIPSG > 15/h, sensitivity was 70%, specificity 91%, PPV 80%, NPV 85%, and +LR was 7.83. The corresponding areas under the receiver operator curves were 0.91 and 0.9. PPG-derived data compare well with simultaneous in-lab PSG in the diagnosis of suspected OSA among patients with and without cardiopulmonary comorbidities. Romem A; Romem A; Koldobskiy D; Scharf SM. Diagnosis of obstructive sleep apnea using pulse oximeter derived photoplethysmographic signals.Keywords
This publication has 34 references indexed in Scilit:
- Treatment of Obstructive Sleep Apnea Reduces the Risk of Atrial Fibrillation Recurrence After Catheter AblationJACC, 2013
- Sleep disordered breathing analysis in a general population using standard pulse oximeter signalsSleep and Breathing, 2013
- RETRACTED: CPAP for the Metabolic Syndrome in Patients with Obstructive Sleep ApneaNew England Journal of Medicine, 2011
- Obstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology EvaluationJournal of Clinical Sleep Medicine, 2011
- Photoplethysmography as a single source for analysis of sleep‐disordered breathing in patients with severe cardiovascular diseaseJournal of Sleep Research, 2011
- An Integrated Health-Economic Analysis of Diagnostic and Therapeutic Strategies in the Treatment of Moderate-to-Severe Obstructive Sleep ApneaSLEEP, 2011
- Continuous positive airway pressure as treatment for systemic hypertension in people with obstructive sleep apnoea: randomised controlled trialBMJ, 2010
- Prospective Study of Obstructive Sleep Apnea and Incident Coronary Heart Disease and Heart FailureCirculation, 2010
- A Cost-Effectiveness Analysis of Alternative At-Home or In-Laboratory Technologies for the Diagnosis of Obstructive Sleep Apnea SyndromeMedical Decision Making, 2001
- Proposed supplements and amendments to ‘A Manual of Standardized Terminology, Techniques and Scoring System for Sleep Stages of Human Subjects’, the Rechtschaffen & Kales (1968) standardPsychiatry and Clinical Neurosciences, 2001