Assessment of knee kinematics with dynamic radiostereometry: Validation of an automated model‐based method of analysis using bone models
- 8 October 2020
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 39 (3) , 597-608
Abstract
Radiostereometic analysis (RSA) is a precise method for the functional assessment of joint kinematics. Traditionally, the method is based on tracking of surgically implanted bone markers and analysis is user intensive. We propose an automated method of analysis based on models generated from computed tomography (CT) scans and digitally reconstructed radiographs. The study investigates method agreement between marker‐based RSA and the CT bone model‐based RSA method for assessment of knee joint kinematics in an experimental setup. Eight cadaveric specimens were prepared with bone markers and bone volume models were generated from CT‐scans. Using a mobile fixture setup, dynamic RSA recordings were obtained during a knee flexion exercise in two unique radiographic setups, uniplanar and biplanar. The method agreement between marker‐based and CT bone model‐based RSA methods was compared using bias and LoA. Results obtained from uniplanar and biplanar recordings were compared and the influence of radiographic setup was considered for clinical relevance. The automated method had a bias of −0.19 mm and 0.11° and LoA within ±0.42 mm and ±0.33° for knee joint translations and rotations, respectively. The model pose estimation of the tibial bone was more precise than the femoral bone. The radiographic setup had no clinically relevant effect on results. In conclusion, the automated CT bone model‐based RSA method had a clinical precision comparable to that of marker‐based RSA. The automated method is non‐invasive, fast, and clinically applicable for functional assessment of knee kinematics and pathomechanics in patients.Keywords
Funding Information
- Fonden til Lægevidenskabens Fremme (19‐L‐0017)
This publication has 30 references indexed in Scilit:
- Automatic determination of anatomical coordinate systems for three-dimensional bone models of the isolated human kneeJournal of Biomechanics, 2010
- Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motionJournal of Orthopaedic Surgery and Research, 2008
- Validation of three-dimensional model-based tibio-femoral tracking during runningMedical Engineering & Physics, 2008
- Model-based RSA of a Femoral Hip Stem Using Surface and Geometrical Shape ModelsClinical Orthopaedics and Related Research, 2006
- Guidelines for standardization of radiostereometry (RSA) of implantsActa Orthopaedica, 2005
- A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy imagesIEEE Transactions on Medical Imaging, 2003
- ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion—part I: ankle, hip, and spineJournal of Biomechanics, 2002
- Methods for determining the accuracy of radiostereometric analysis (RSA)Acta Orthopaedica, 2000
- Determining the movements of the skeleton using well-configured markersJournal of Biomechanics, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986