Retrograde flow in the dural sinuses detected by three-dimensional time-of-flight MR angiography
Authors:
- 16 December 2006
- journal article
- research article
- Published by Springer Nature in Neuroradiology
- Vol. 49 (3) , 211-215
Abstract
Introduction Retrograde flow in the left dural sinuses is sometimes detected by three-dimensional time-of-flight (3D-TOF) magnetic resonance (MR) angiography. The purpose of this study was to evaluate the incidence of this phenomenon and its characteristic features on 3D-TOF MR angiograms. Methods We retrospectively reviewed cranial MR angiography images of 1,078 patients examined at our institution. All images were obtained by the 3D-TOF technique with one of two 1.5-T scanners. Maximum intensity projection (MIP) images in the horizontal rotation view were displayed stereoscopically. We reviewed the source images, inferosuperior MIP images, and horizontal MIP images and identified retrograde flow in the dural sinuses. Results We found retrograde flow in the dural sinuses of 67 patients on the source images from 3D-TOF MR angiography; the incidence was 6.2%. In 47 of the 67 patients, retrograde flow was identified in the left inferior petrosal sinus, in 13, it was seen in the left sigmoid sinus, and in 6, it was seen in the left inferior petrosal and left sigmoid sinuses. The remaining patient had retrograde flow in the left inferior petrosal and left and right sigmoid sinuses. The mean age of the patients with retrograde flow was slightly greater than that of the patients without this phenomenon (70 years vs 63 years). Conclusion Retrograde flow in the dural sinuses frequently occurs on the left side in middle-aged and elderly patients during 3D-TOF MR angiography performed with the patient in the supine position. This phenomenon should not be misdiagnosed as a dural arteriovenous fistula.Keywords
This publication has 12 references indexed in Scilit:
- Detection of intracranial venous reflux in patients of transient global amnesiaNeurology, 2006
- Physiologic Change in Flow Velocity and Direction of Dural Venous Sinuses with Respiration: MR Venography and Flow Analysis2004
- Retrograde Flow in the Left Inferior Petrosal Sinus and Blood Steal of the Cavernous Sinus Associated with Central Vein Stenosis: MR Angiographic Findings2003
- Suboptimal contrast-enhanced carotid MR angiography from the left brachiocephalic venous stasisJournal of Magnetic Resonance Imaging, 1999
- Cavernous Sinus and Inferior Petrosal Sinus Flow Signal on Three-Dimensional Time-of-Flight MR Angiography1999
- Three-dimensional FISP imaging in the evaluation of carotid cavernous fistula: comparison with contrast-enhanced CT and spin-echo MR.1998
- Diagnosis of carotid-cavernous fistulas with magnetic resonance angiography?demonstrating the draining veins utilizing 3-D time-of-flight and 3-D phase-contrast techniquesNeurosurgical Review, 1996
- Compression of the left brachiocephalic vein: cause of high signal intensity of the left sigmoid sinus and internal jugular vein on MR images.Radiology, 1993
- Follow-up MRI in dural arteriovenous malformations involving the cavernous sinus: emphasis on detection of venous thrombosisNeuroradiology, 1992
- The Effects of Injection Site, Age, and Body Position on Cervical Venous RefluxRadiology, 1979