Abstract
Wars and conflicts that were resolved even decades ago have the lingering danger of unexploded ordinances. Remediation of these explosive devices is particularly hazardous and time consuming when there are landmines or improvised explosive devices (IEDs) that are buried. A common detection method employs canines, which are able to sniff out devices based on the emission of volatile organic compounds (VOCs), even at minute levels. When an explosive device is buried, VOCs must travel through the soil to the surface. This process introduces sources of vapor loss, notably sorption to the soil, limiting vapor availability. This study considers the impact of various conditions on the simulated burial of two explosive-related compounds: 2,4-dinitrotolune (DNT) a degradant and contaminant from TNT and 2,3-dimethyl-2,3-dinitrobutane (DMNB) a common taggant in C-4. Headspace solid phase microextraction (HS-SPME) was used to measure free volatiles at varying heights along a simulated burial temporally, providing quantitative evidence of the gaseous diffusion process. A driving force of vapor transport was confirmed to be evapotranspiration, as conditions with moisture and sunlight resulted in higher concentrations of analyte present. Additionally, stronger adsorption to soil indicated that environments with a higher sand content are likely to have more successful detection of buried explosives. Complementary canine olfactory trials were conducted for comparison to the laboratory study. This work points to environments where detection of a buried explosive device is more likely to be successful or limited.