Removal of Lipid Artifacts in Amide Proton Transfer Imaging Using Differential Analysis With Fitted Magnetization Transfer and Lipid Signals ( DIGITAL )
- 20 April 2026
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (2) , 756-770
Abstract
Purpose: A differential analysis with fitted magnetization transfer and lipid signals (DIGITAL) method is proposed for eliminating fat artifacts and accurately extracting amide proton transfer (APT) contrast in lipid‐rich regions. Theory and Methods: The DIGITAL method integrates a two‐pool water‐magnetization transfer (MT) Bloch‐McConnell (BM) model with a six‐peak fat Bloch model. Renormalization is employed to correct fat‐induced Z‐spectrum distortion, and APT # signals are calculated by subtracting the fitted Z‐spectrum from the raw Z‐spectrum. The proposed DIGITAL method was evaluated using numerical simulations, phantoms, and breast tumor data, with its performance compared against prior multi‐pool Lorentzian (MPL) and numerical fitting of extrapolated semisolid magnetization transfer reference signals (NEMR) methods. We also developed a voxel‐wise reliability map to assess data and fit quality. Results: In simulations and experiments, renormalization effectively corrected fat‐induced signal scaling and restored the Z‐spectrum value at 0 ppm to near 0. The proposed DIGITAL method demonstrated superior uniformity in APT # maps compared to MPL and NEMR. Moreover, DIGITAL was minimally affected by fat, exhibiting high robustness against variations in fat concentrations and a strong linear relationship with amide proton concentrations. In addition, the reliability map functioned as an essential quality assurance tool, enabling the identification of outliers and improving the overall precision of APT analysis. Conclusion: The proposed DIGITAL method can effectively eliminate fat artifacts and extract accurate APT signals without requiring sequence modifications, offering a promising solution to the long‐standing challenge of lipid contamination in body APT imaging.Keywords
Funding Information
- National Key Research and Development Program of China (2024YFC2707700)
- National Key Research and Development Program of China (2023YFE0210300)
- Fundamental Research Funds for the Central Universities (2025ZFJH01)
This publication has 60 references indexed in Scilit:
- Breast Amide Proton Transfer Imaging at 3 T: Diagnostic Performance and Association With Pathologic CharacteristicsJournal of Magnetic Resonance Imaging, 2022
- Selecting the reference image for registration of CEST seriesJournal of Magnetic Resonance Imaging, 2015
- Dixon techniques for water and fat imagingJournal of Magnetic Resonance Imaging, 2008
- Evaluation of optimized inversion‐recovery fat‐suppression techniques for T2‐weighted abdominal MR imagingJournal of Magnetic Resonance Imaging, 2008
- Multiecho reconstruction for simultaneous water‐fat decomposition and T2* estimationJournal of Magnetic Resonance Imaging, 2007
- Multicoil Dixon chemical species separation with an iterative least‐squares estimation methodMagnetic Resonance in Medicine, 2003
- Amide proton transfer (APT) contrast for imaging of brain tumorsMagnetic Resonance in Medicine, 2003
- Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRIMagnetic Resonance in Medicine, 2001
- Separation of fat and water in fast spin‐echo MR imaging with the three‐point dixon techniqueJournal of Magnetic Resonance Imaging, 1995
- Quantitative interpretation of magnetization transferMagnetic Resonance in Medicine, 1993