Fragility of open-topped oil storage tanks under wind in Patagonia
Open Access
- 1 January 2023
- journal article
- Published by Maximum Academic Press in Emergency Management Science and Technology
- Vol. 3 (1) , 1-10
Abstract
Oil storage tank farms are complex systems and the eventual failure of one of their components could affect the whole system. A risk assessment requires identifying the magnitude of the damage that can occur under certain load level. Fragility curves for oil storage tanks with a floating roof are obtained in this work, to estimate the probability of exceeding a given damage state under wind loads. Steel tanks with height-diameter ratio between 0.20 and 0.60 designed with American Petroleum Institute standard 650 are analyzed. The loads are represented by wind- speed and the structural response of the tank is evaluated through computational simulations using finite element analyses. Damage is characterized by deformations in the geometry of the cylinder and wind girder. Damage levels are obtained using linear bifurcation analysis and geometric nonlinear analysis with imperfections, and loads are related to wind speed based on wind data of Patagonia in Argentina. The fragility curves are constructed by means of a log-normal distribution. The results allow establishing ranges of wind speeds for which the damage can affect the integrity of the tank. It is expected that the present results serve as the basis for the development of simplified models, so that a much larger tank database may be taken into account.Keywords
This publication has 31 references indexed in Scilit:
- Wind Loads for Designing Cylindrical Storage Tanks Part 1 Characteristics of Wind Pressure and Force DistributionsJournal of Wind Engineering, 2012
- Reduced Stiffness Buckling Analysis of Aboveground Storage Tanks with Thickness ChangesAdvances in Structural Engineering, 2011
- Challenges in the computation of lower-bound buckling loads for tanks under wind pressuresThin-Walled Structures, 2010
- Petroleum and Hazardous Material Releases from Industrial Facilities Associated with Hurricane KatrinaRisk Analysis, 2010
- A reduced stiffness approach for the buckling of open cylindrical tanks under wind loadsThin-Walled Structures, 2007
- Design Analysis for Buckling of Tanks and SilosJournal of Structural Engineering, 2006
- Computational fluid dynamics study of flow around floating-roof oil storage tanksJournal of Wind Engineering and Industrial Aerodynamics, 2000
- Wind loads on circular storage bins, silos and tanks: I. Point pressure measurements on isolated structuresJournal of Wind Engineering and Industrial Aerodynamics, 1988
- An incremental approach to the solution of snapping and buckling problemsInternational Journal of Solids and Structures, 1979
- The Application of Newton’s Method to the Problem of Elastic StabilityJournal of Applied Mechanics, 1972