Highly sensitive formaldehyde sensors based on polyvinylamine modified polyacrylonitrile nanofibers
- 25 September 2013
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 3 (45) , 22994-23000
Abstract
A novel, sensitive, selective, and reproductive formaldehyde sensor has been developed by coating polyvinylamine (PVAm) modified electrospun polyacrylonitrile (PAN) nanofibrous membranes on quartz crystal microbalance (QCM) for the first time. Benefiting from the abundant primary amine groups in PVAm, large specific surface area, high porosity and hierarchal structure of PAN nanofibers, and the strong interaction between PVAm molecule and formaldehyde, the as-prepared QCM sensors achieved an extremely low detection limit of 500 ppb in a remarkably short period of time (120 s). Moreover, the sensitivity of the fibrous membranes based sensors are 2.5 times higher than that of flat film-based ones when upon exposure to 500 ppb formaldehyde. Furthermore, the as-prepared QCM sensors possess excellent reproducibility, reversibility, and good selectivity by virtue of the reversible nucleophilic addition reaction between formaldehyde molecule and primary amine group in PVAm. Hence, such promising QCM sensors could not only potentially allow for monitoring gaseous formaldehyde, but also pave a way for designing and development of novel QCM sensing systems based on functionalized nanofibrous membranes.Keywords
This publication has 27 references indexed in Scilit:
- Nanoporous polystyrene fibers functionalized by polyethyleneimine for enhanced formaldehyde sensingSensors and Actuators B: Chemical, 2011
- Cancer effects of formaldehyde: a proposal for an indoor air guideline valueArchives of Toxicology, 2010
- A self-assembling nanoparticle for paclitaxel delivery in ovarian cancerBiomaterials, 2009
- An Ecological Risk Assessment of FormaldehydeHuman and Ecological Risk Assessment: An International Journal, 2003
- Molecular imprinted polymer coated QCM for the detection of nandroloneThe Analyst, 2002
- Molecular-Imprinted, Polymer-Coated Quartz Crystal Microbalances for the Detection of TerpenesAnalytical Chemistry, 2001
- Electrochemical enzyme sensor for formaldehyde operating in the gas phaseBiosensors and Bioelectronics, 1996
- Measurement of interfacial processes at electrode surfaces with the electrochemical quartz crystal microbalanceChemical Reviews, 1992
- Characterization of a quartz crystal microbalance with simultaneous mass and liquid loadingAnalytical Chemistry, 1991
- Nanotribology of a Kr monolayer: A quartz-crystal microbalance study of atomic-scale frictionPhysical Review Letters, 1991