Reducing Alarm Burden in a Level IV Neonatal Intensive Care Unit
Open Access
- 12 February 2021
- journal article
- research article
- Published by Wolters Kluwer Health in Pediatric Quality & Safety
- Vol. 6 (2) , e386
Abstract
Introduction: Excessive alarm burden contributes to alarm fatigue, causing staff to ignore or delay response to clinically significant alarms. The objective of this quality improvement project was to reduce yellow self-resolving SpO2 alarms from a mean of 14 alarms/patient-hour (APH) to 7 APH (a 50% reduction) within a 6-month period, without significantly decreasing the amount of time spent in target SpO2 range (90%–95%). Methods: A multidisciplinary team used Define-Measure-Analyze-Improve-Control methodology to identify etiologies of alarm frequency and design improvement interventions to reduce alarm burden in a single-site Level IV NICU. Data-driven changes in alarm limit settings, alarm delay, and trial of a new pulse oximeter probe were used. Alarm data from the bedside monitor were analyzed following each improvement cycle. As a balancing measure, histograms monitored time spent in target SpO2 range. Results: SpO2 alarm data were collected for 4,320 patient-hours (180 patient-days) on 40 neonatal intensive care unit patients meeting inclusion criteria. Corresponding histograms were obtained for each patient day. Following 5 Plan-Do-Study-Act cycles, the mean number of yellow self-resolving SpO2 alarms decreased from 14 to 5 APH, a 64% decrease. There was no difference in time spent in target SpO2 range (50% versus 50%, P = 0.93). After achieving the project aim, 2 control phase measurements demonstrated sustained improvement (mean APH = 6). Conclusions: Yellow self-resolving SpO2 alarm frequency was reduced by 64% through the implementation of data-driven changes in alarm limit settings, alarm delays, and trial of a more sensitive oximeter probe without introducing harm to patients.Keywords
This publication has 23 references indexed in Scilit:
- Automated versus Manual Oxygen Control with Different Saturation Targets and Modes of Respiratory Support in Preterm InfantsThe Journal of Pediatrics, 2015
- Balancing the Tension Between Hyperoxia Prevention and Alarm Fatigue in the NICUPediatrics, 2015
- The Effect of Alarm Fatigue on the Work EnvironmentAACN Advanced Critical Care, 2014
- Improving Medical Device Alarm Safety in HospitalsJournal of Nursing Care Quality, 2013
- Joint Commission Warns of Alarm FatigueJAMA, 2013
- Monitor Alarm Fatigue : An Integrative ReviewBiomedical Instrumentation & Technology, 2012
- High or Low Oxygen Saturation and Severe Retinopathy of Prematurity: A Meta-analysisPediatrics, 2010
- Alarms in the intensive care unit: Too much of a good thing is dangerous: Is it time to add some intelligence to alarms?*Critical Care Medicine, 2010
- Monitor Alarm Fatigue: Standardizing Use of Physiological Monitors and Decreasing Nuisance AlarmsAmerican Journal of Critical Care, 2010
- False alarms in very low birthweight infants: comparison between three intensive care monitoring systemsActa Paediatrica, 2000