Improved diagnostic value of a TCD-based non-invasive ICP measurement method compared with the sonographic ONSD method for detecting elevated intracranial pressure
Authors:
- Arminas RagauskasARArminas Ragauskas
- Laimonas BartusisLBLaimonas Bartusis
- Ian PiperIPIan Piper
- Rolandas ZakelisRZRolandas Zakelis
- Vaidas MatijosaitisVMVaidas Matijosaitis
- Kestutis PetrikonisKPKestutis Petrikonis
- Daiva RastenyteDRDaiva Rastenyte
- 12 January 2014
- journal article
- clinical trial
- Published by Taylor & Francis in Neurological Research
- Vol. 36 (7) , 607-614
Abstract
To compare the diagnostic reliability of optic nerve sheath diameter (ONSD) ultrasonography with a transcranial Doppler (TCD)-based absolute intracranial pressure (ICP) value measurement method for detection of elevated ICP in neurological patients. The ONSD method has been only tested previously on neurosurgical patients. A prospective clinical study of a non-invasive ICP estimation method based on ONSD correlation with ICP and an absolute ICP value measurement method based on a two-depth TCD technology has recruited 108 neurological patients. Ninety-two of these patients have been enrolled in the final analysis of the diagnostic reliability of ONSD ultrasonography and 85 patients using the absolute ICP value measurement method. All non-invasive ICP measurements were compared with 'Gold Standard' invasive cerebrospinal fluid (CSF) pressure measurements obtained by lumbar puncture. Receiver-operating characteristic (ROC) analysis has been used to investigate the diagnostic value of these two methods. The diagnostic sensitivity, specificity, and the area under the ROC curve (AUC) of the ONSD method for detecting elevated intracranial pressure (ICP >14·7 mmHg) were calculated using a cutoff point of ONSD at 5·0 mm and found to be 37·0%, 58·5%, and 0·57, respectively. The diagnostic sensitivity, specificity, and AUC for the non-invasive absolute ICP measurement method were calculated at the same ICP cutoff point of 14·7 mmHg and were determined to be 68·0%, 84·3%, and 0·87, respectively. The non-invasive ICP measurement method based on two-depth TCD technology has a better diagnostic reliability on neurological patients than the ONSD method when expressed by the sensitivity and specificity for detecting elevated ICP >14·7 mmHg.Keywords
This publication has 30 references indexed in Scilit:
- Intensive Care Treatment Options of Elevated Intracranial Pressure Following Severe Traumatic Brain Injury2010
- Metabolic failure precedes intracranial pressure rises in traumatic brain injury: a microdialysis studyActa Neurochirurgica, 2008
- Correlation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial PressureAcademic Emergency Medicine, 2008
- Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injuryIntensive Care Medicine, 2007
- Transcranial Doppler sonography pulsatility index (PI) reflects intracranial pressure (ICP)Surgical Neurology, 2004
- Monitoring and interpretation of intracranial pressureJournal of Neurology, Neurosurgery & Psychiatry, 2004
- Critical care management of head trauma in childrenCritical Care Medicine, 2002
- "Normal pressure hydrocephalus": what's in a name?Journal of Neurology, Neurosurgery & Psychiatry, 2002
- Otoacoustic emissions: a new tool for monitoring intracranial pressure changes through stapes displacementsHearing Research, 1996
- Noninvasive Intracranial Pressure MonitoringNeurosurgery, 1985