Fatal intoxication with U-47700 in combination with other NPS (N-ethylhexedrone, adinazolam, 4-CIC, 4-CMC) confirmed by identification and quantification in autopsy specimens and evidences
Open Access
- 19 January 2021
- journal article
- case report
- Published by Springer Nature in Forensic Toxicology
- Vol. 39 (2) , 493-505
Abstract
Purpose: We present a case of fatal intoxication with U-47700 in combination with other NPS (N-ethylhexedrone, adinazolam, 4-chloro-N-isopropylcathinone (4-CIC), 4-chloromethcathinone (4-CMC) and sertraline) confirmed by identification and quantification in biological materials and evidences found at the scene in 2017 in Poland. Methods: Blood and urine samples were extracted with ethyl acetate from alkaline medium (pH 9); powders/crystals were diluted with methanol. The analysis was carried out using ultra-high-performance liquid chromatography–tandem mass spectrometry. Validation criteria were evaluated for blood and urine at the concentrations of 10 and 100 ng/mL. Results: The validation parameters of the method were within acceptable ranges. In the presented case, the determined concentrations of drugs were as follows, in blood: U-47700, 1470 ng/mL; N-ethylhexedrone, 58 ng/mL; adinazolam, 18 ng/mL; 4-CIC, 8.0 ng/mL; 4-CMC, 1.7 ng/mL; in urine: U-47700, 3940 ng/mL; N-ethylhexedrone, 147 ng/mL; adinazolam, 82 ng/mL; 4-CIC, 130 ng/mL; 4-CMC, 417 ng/mL. Sertraline (blood, 89 ng/mL; urine, 32 ng/mL) was also determined in both materials. The same substances were also found in 5 powders/crystals: U-47700 (12% by weight), N-ethylhexedrone (54%), adinazolam (14%), 4-CIC (23%), 4-CMC (26%). After 775 days of storage, biological samples at + 4 °C, the most stable substance was sertraline and the less, synthetic cathinones, especially 4-CIC and 4-CMC. Conclusions: The described case of fatal intoxication with NPS presented postmortem concentrations of U-47700, 4-CMC, N-ethylhexedrone, adinazolam and 4-CIC for the first time in the literature. The paper also showed stability study of these substances stored at + 4 °C for 775 days.Keywords
This publication has 29 references indexed in Scilit:
- Analysis of U-47700, a Novel Synthetic Opioid, in Human Urine by LC–MS–MS and LC–QToFJournal of Analytical Toxicology, 2016
- U-47700. An old opioid becomes a recent dangerForensic Toxicology, 2016
- A Fatality Related to the Synthetic Opioid U-47700: Postmortem Concentration DistributionJournal of Analytical Toxicology, 2016
- Characterization and in vitro phase I microsomal metabolism of designer benzodiazepines — an update comprising adinazolam, cloniprazepam, fonazepam, 3‐hydroxyphenazepam, metizolam and nitrazolamJournal of Mass Spectrometry, 2016
- Analysis of Novel Synthetic Opioids U-47700, U-50488 and Furanyl Fentanyl by LC–MS/MS in Postmortem CaseworkJournal of Analytical Toxicology, 2016
- A case of acute intoxication due to combined use of fentanyl and 3,4-dichloro-N-[2-(dimethylamino)cyclohexyl]-N-methylbenzamide (U-47700)Forensic Science International, 2016
- Suicide attempt with a mix of synthetic cannabinoids and synthetic cathinones: Case report of non-fatal intoxication with AB-CHMINACA, AB-FUBINACA, alpha-PHP, alpha-PVP and 4-CMCForensic Science International, 2016
- The first reported fatality associated with the synthetic opioid 3,4‐dichloro‐N‐[2‐(dimethylamino)cyclohexyl]‐N‐methylbenzamide (U‐47700) and implications for forensic analysisDrug Testing and Analysis, 2016
- Determination of Sertraline in Human Plasma by UPLC–MS/MS and its Application to a Pharmacokinetic StudyJournal of Chromatographic Science, 2015
- Benzodiazepine Stability in Postmortem Samples Stored at Different TemperaturesJournal of Analytical Toxicology, 2012