Abstract
We have realized a micro Coriolis mass flow sensor that is actuated by integrated lead zirconate titanate (PZT) thin film actuators, allowing low voltage, low power actuation compared to current actuation methods. The integrated PZT thin film actuators are deposited on top of silicon-rich silicon nitride (SiRN) fluidic microchannels by pulsed laser deposition (PLD). In this paper we present the fabrication process and first characterization results, including a mass flow measurement with nitrogen flow using a Polytec MSA-400 laser Doppler vibrometer to detect the Coriolis induced motion of the sensor tube. The measurement results confirm that the sensor output is proportional to mass flow up to 14 mg/min.Keywords
This publication has 6 references indexed in Scilit:
- A versatile technology platform for microfluidic handling systems, part I: fabrication and functionalizationMicrofluidics and Nanofluidics, 2017
- The past, present and potential for microfluidic reactor technology in chemical synthesisNature Chemistry, 2013
- Compact Mass Flow Meter Based on a Micro Coriolis Flow SensorMicromachines, 2013
- Characterization of epitaxial Pb(Zr,Ti)O3thin films deposited by pulsed laser deposition on silicon cantileversJournal of Micromechanics and Microengineering, 2010
- Lab-on-a-Chip: A Revolution in Biological and Medical Sciences.Analytical Chemistry, 2000
- A silicon resonant sensor structure for Coriolis mass-flow measurementsJournal of Microelectromechanical Systems, 1997